•Assemble the large and small spray gun clips to the side of the tank using two #10 x 1/2" screws and #10 lock washers. See figure 7.
#10 x 1/2"
SCREW
SPRAY GUN |
| |
#10 LOCK CLIP (LARGE) | SPRAY GUN | |
WASHER | ||
CLIP (SMALL) | ||
|
FIGURE 7
3/8" HOSE CLAMPS
COILED HOSE CLAMP
SPRAY GUN |
| ON - OFF | BOOM |
| VALVE | CONNECTING | |
HOSE |
| ||
| CONDUIT | HOSE | |
| 1/4" TEE | ||
| CLAMP |
| |
|
|
| |
FIGURE 8 |
| VIEWED FROM FRONT |
•To connect the wire harness to the tractor, attach the red wire to the positive post on the battery or to the "HOT" connection on a tractor switch or ammeter. The brown wire may be grounded or connected to the negative battery post. See figures 9 and 10.
IMPORTANT: This sprayer should be connected to 12 volt batteries only!
•Slide a 3/8" hose clamp onto the boom connecting hose. Place the end of the hose through the conduit clamp (attached to the pump) and then slide a second 3/8" hose clamp onto the hose. Leave hose clamps loose for now. See Figure 8.
•Push the hose onto the hose adapter in the end of the
•Position the valve and hose clamp up against the conduit clamp. Slide the other hose clamp against the other side of the conduit clamp. Tighten the clamp without collapsing the hose. See figure 8.
•Slide the coiled hose clamp onto the spray gun hose and then push the hose onto the hose adapter on the
1/4" tee fitting. Tighten the hose clamp around the hose and adapter. See figure 8.
•Snap the spray gun into the clips on the front of the tank. (The large clip holds the spray gun handle and the small clip holds the wand.) Refer to figure 7.
PUMP SWITCH QUICK COUPLER
RED | RED | + |
| ||
|
| BATTERY |
BROWN | BROWN |
|
FIGURE 9
DANGER! Never allow negative pin on plug to come in contact with positive "hot" post on battery. Fire or explosion may result!
PLUG | + | POSITIVE | |
"HOT" | |||
| |||
|
| POST |
| NEGATIVE |
NEGATIVE PIN | POST |
| |
| 12 VOLT TRACTOR BATTERY |
FIGURE 10
6