Sears 583.35683 Trouble- Shooting, Possible Cause, Wrong pump pressure, Flame-out, before, heater

Models: 583.35682 583.35683 583.3565

1 24
Download 24 pages 36.09 Kb
Page 9
Image 9
TROUBLE- SHOOTING

TROUBLE- SHOOTING

WARNING

Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur.

OBSERVED FAULT

Heater ignites, but flame-out control shuts off heater after

a short period of time.

Heater will not

ignite, but motor runs for a short period of time.

POSSIBLE CAUSE

Wrong pump pressure

Dirty air output, air intake and lint filters

Dirty fuel filter

Dirt in nozzle

Dirty photocell lens

Bad flame-out control

Wrong pump pressure

Carbon deposits on spark plug and!or improper gap

Dirty fuel filter

Dirt in nozzle

Water in fuel tank

REMEDY
See Pump Pressure Adjustment, page 11.

See Air Output, Air Intake, and Lint Filters, page 10.

See Fuel Filter, page 11.

See Nozzle, pages 12 and 13.

Clean photocell lens.

Replace flame-out control.

See Pump Pressure Adjustment, page 11.

See Spark Plug, pages 11 and 12.

See Fuel Filter, page 11.

See Nozzle, page 12 and 13.

Drain and flush fuel tank with clean kerosene. See Storing, Tramporti_, or S_ippi_, above, page 8.

_Ib WARNING: High Voltage!

 

 

Electronic ignitor not

Make sure electronic

grounded

ignitor

mounting

is tight.

Bad electronic ignitor

Replace

electronic

ignitor.

Motor does not start when heater is plugged in, fan rotates slowly or does not turn.

Flame-out

control not reset Press flame-out

control

 

 

reset

button.

 

 

 

Solid state

relay not

Wait two minutes

before

allowed

to reset

trying to restart

heater.

Binding pump rotor

If fan

is hard to

turn,

see

 

 

PumpRotor,

page

13.

100506

Page 9
Image 9
Sears 583.35683 Trouble- Shooting, Possible Cause, Wrong pump pressure, Flame-out, control not reset Press flame-out, Pump