Sears 801RFD, 249RP, 245 Sounds, Product Operation, Temperature Control Location And Adjustments

Models: 249FF 249R 245 249RP 801RFD

1 8
Download 8 pages 44.55 Kb
Page 5
Image 5
PRODUCT OPERATION

_

IIIIII11

II({I

 

_o -

 

,,,,H,H,,H,

III"

PRODUCT OPERATION

 

I 'IH I

I

 

I

....

'

 

l'll

I

The importance of the Installation of your Sub-Zero CANNOT be overemphasized. The proper installation of your unit is the responsibility of the selling dealer or installer. Any questions or problems pertaining to the installation should be directed to the selling dealer.

TEMPERATURE CONTROL LOCATION AND ADJUSTMENTS

-Your new refrigerator and/or freezer was thoroughly inspected and tested before it was shipped from the Sub-Zero factory. During these procedures, the temperatures were preset to maintain approximately 38 degrees in the refrigerator section and approximately 0 degrees in the freezer section (except 249R). If you wish to make temperature adjustments, simply turn the

temperature control dial. The higher the number the colder the temperature (#1 is the warmest and #7 is the coldest setting). For the location of the control, refer to the model of your Sub-Zero on the following pages.

You should be aware it is normal for the above temperatures to fluctuate slightly, depending on external influence such as: open door for extended periods, the degree of humidity present and room tem- perature.

.4) ADJUSTMENT

To adjust the freezer and refrigerator controls on our models 245, 249R, 249RP,

249FF and 801RFD, simply turn the control knob so the indicator lines up with the desired number.

B)LOCATION MODEL 245

The freezer control is located on the back

wall above and right of the ic_emaker assembly. (See Model 245 Features on

page 3.) The refrigerator control is situated left of center at the top of the refrigerator compartment. (See Model 245 Features on page 3.)

MODEL 249R

(MANUAL DEFROST)

The control is situated on the right hand side of the back wall in the upper freezer corn artment. See

on pageant.) 1._ Model 249RP Features

MODEL 249RP

The control is located on the right side of the back wall just below the lower shelf assembly. (See Model 249RP Features on page 3.)

MODEL 249FF

The control is found at the top of the freezer on the right side of the defrost blower assembly. (See Model 249FF Features on page 4.)

MODEL 801 RFD

The refrigerator control is located on the top left wall of the refrigerator compartment as you face the unit. (See Model 801 RFD Features on page 4.) The freezer control is situated on the right side of the automatic defrost blower assembly located at the top of the freezer compartment. (See Model 801RFD Features on page 4.)

DOOR CLOSING

MODELS 245 and 801RFD

The doors on our models 245 and 801RFD are equipped with a door closing cam system to assist in the closing of the door. As you close the door, the cam will take over at approximately the 15 degree posi- tion to assist in the closing of the door.

MODELS 249R, 249RP and 249FF

The refrigerator and freezer doors are both equipped with a spring-loaded door clo- sure mechanism. As the doors are closed, the door closure engages at approximately the 15 degree position to assist the door in closing and sealing.

CONDENSER FAN

OPERATION

All undercounter units have one fan located

behind the kickplate at the base of the unit. On all undercounter models the fan

operates on/ywhen the compressor is run- ning.

EVAPORATOR FAN

OPERATION

MODELS 245, 249FF and 801RFD

Afan motor is located in the freezer section on the models listed above. These fans operate onlywhen the compressor is running.

AUTOMATIC DEFROST INFORMATION

For your convenience, Sub-Zero has equipped the following models with an automatic defrost system: 245, 249RP, 249FF and 801RFD. NOTE: Our model 249R is not equipped with automatic defrost. To manually defrost, turn the a control knob to the off position.

SOUNDS

Certain noises may be evident with the

normal operation of the unit. Surrounding acoustics like walls, floors and cabinets may affect the sound level of your unit.

A gurgling sound or running water sound may be evident as the refrigerant circulates through the tubing.

During the icemaker cycle, you may hear the sound of ice dropping into the bucket or the solenoid valve while refilling the ice- maker with water.

During the freezer defrost, you may hear crackling and/or sizzling as the heat from the defrost element clears the frost from the freezer coil and water runs into the defrost water pan.

While the compressors are in operation, a slight hum might be evident. During the startup and shutdown of the compressor,

some vibration may occur lasting only a few seconds.

ICEMAKER OPERATION

The icemaker in your Sub-Zero is fully auto- matic and has been factory pretested. To put into operation, it requires only a con- nection to the house water supply.

Page 5
Image 5
Sears 801RFD Sounds, Product Operation, Temperature Control Location And Adjustments, Door Closing, Icemaker Operation