SERVUCE ADJUSTMENTS
ENGINE
TO ADJUST THROTTLE CONTROL CABLE
(See Fig. 33)
The throttle control has been preset at the factory and adjustment should not be necessary. Check adjustment as described below before loosening eable. If adjustment is necessary, proceed as follows:
•With engine not running, move throttle control lever to fast (,@) position.
oCheck that speed control lever is against stop screw. If it is not, loosen casing clamp screw and pull throttle cable until lever is against screw. Tighten clamp screw securely
IDLE FUEL
ADJUSTING IDLE SPEED
NEEDLEADJUSTING
SCREW
THROTTLE
CONTROL
CABLE
TO ADJUST CHOKE CONTROL
(See Figs. 33 and 34)
The choke control has been preset at the factory and adjustment should not be necessary check adjustment as described below before loosening cable. If adjustment is necessary, proceed as follows:
With engine not running, move choke control (located on dash panel) to full choke (I\l) position
,Remove air cleaner cover, filter and cartridge plate to expose carburetor choke (See "AIR FILTER" in the Customer Responsibilities section of this manual)
Choke should be closed, If it is not, loosen casing clamp screw and move choke cable until choke is completely closed. Tighten casing clamp screw se- curely.
Reassemble air cleaner
CLOSED FOR
FIGo 34
STOP
SCREW
CLAMPCHOKE
SCREWCONTROL
CABLE
FIG. 33
25