Service and Adjustment

Tank (Sediment) Cleaning

Sediment build-up on the tank bottom may create varying
amounts of noise, and if left in the tank will cause premature
tank failure. In some water areas, you may not be able to drain
all sediment deposits by simply draining the tank. In these cases
Mag Erad (part no. 3515) can be used to help remove the sedi-
ment deposits. This may be ordered from the Sears Service
Center. For orderirlg, referto the "Parrs Order List" section.
AWARNING ]
Soot build.upindicatesaproblem that requires correction|
beforefurtheruse.Turn"OFF" gasto water heaterand leave|
"OFF" until repairs aremade, becausefailureto correct the/
causeofthe sootingcanresult ina fire or explosioncausing|
DEATH,SERIOUSBODILYINJURY,ORPROPERTYDAMAGE.|

Venting System inspection

At least once a year avisual inspection should be made of the
venting system. Youshould look mr:
oObstructions which could cause improper venting. The com-
bustion and ventilation air flowmust not be obstructed.
Damage or deterioration which could cause improper venting
or leakage of combustion products.
Rusted flakes around top of water heater.
AWARNING
Chemicalvapor corrosion of the flue andvent systemmay i
occurif air for combustioncontainscertainchemicalvapors.
Spraycanpropellants,cleaningsolvents,refrigerator andair
conditionerrefrigerants,swlmmlngpool chemicals, calcium
andsodiumchloride,waxes,bleach,and processchemicalsare
typicalcompoundswhicharepotentiallycorrosive.

Burner Cleaning

In the event your burner needs cleaning, use the following
instructions:
If inspection of the burner shows that deaning is required, turn
the gas control knob clockwise (_"_) to the "OFF" position,
depressing slightly.
NOTE: The knob cannot be turned from "PILOT" to "OFF"
unless knob is depressed slightly. DO NOT FORCE.
Loose deposits on or around the burner can be removed by care-
fully using the hose of a vacuum cleaner inserted through the
accessdoor of the water heater.If the burner needs to be removed
for additional cleaning, calf the Sears Service Center to remove
and clean the burner and correct the problem that required the
burner to be cleaned.
AWARNING
Obstructedordeterioratedventsystemsmaypresenta serious
healthriskor asphyxiation.
AWARNING
1Besure the vent pipingis properly connected to prevent
Iescapeof dangerousflue gasseswhich could causedeadly
[asphyxiation.
AWARNING
if after inspectionof the vent system you found sootingor
deterioration,somethingiswrong.Callthe localgasutility to
correctthe problemandcleanor replace theflue andventing
beforeresumingoperationof the water heater.

Burner Inspection

AWARNING {
Do notusethisapplianceifanypart ofit hasbeenunderwater.
Immediately call a Sears ServiceTechnicianto inspectthe
applianceand to replace the gascontrol or any part of the
burnersystem which has been under water. {
At least once a year a visual inspection should be made of the
main burner and pilor burner. The drawing is for your reference.
You should check for sooting which is not normal and wil!
impair proper combustion.
2O

L.R Gas Control Valve & Burner

Assembly Replacement

Information

AWARNING
PROPANE (L.R) GAS CONTROL VALVE AND BURNER
ASSEMBLYREPLACEMENT INFORMATION.
For Propane (LP.) Gas Models Only:
Yourwater heater is equipped with a Propane (LR) gas
control valve and a mainburner assemblywith left hand
threads for the following fittings and their connections.
(I) The connection between the manifold and the
gas control valve (A to B) are left hand threads.
(2) The connection between the main burner ori-
fice and the manifold (C to D) are left hand
threads. For ordering these replacement parts,
please refer to the "Parts Order List" section of
this manual.