SECO-LARM USA EV-2221-NKBQ manual Overview, Before Starting, Installation, Varifocal models only

Models: EV-2801-NKBQ

1 4
Download 4 pages 20.09 Kb
Page 3
Image 3
Overview:

Overview:

 

Latch

To remove the

 

 

 

mounting base,

 

 

release the latch.

 

Mounting base

 

Arrow

 

 

 

Mounting

 

 

screws

 

Punch-out

Female BNC

 

 

 

DC plug with

connector

 

 

 

terminal block

 

 

DC jack

SECO-LARM Indoor IR Dome Cameras

Important:

Do not cut the DC jack or the female BNC connector as this will void the warranty.

Camera

Camera cover

Dome cover

Varifocal models only

Focus

Varifocal models only Zoom

Before Starting:

1.Please read this manual carefully and keep it for future reference.

2.Use the camera within given temperature and electrical limits.

3.Do not aim the LED light directly at the eyes when the LEDs are on.

4.Do not point the camera at the sun. Heat could damage the camera, even when not in use.

5.Do not mount the camera in areas exposed to radiation, strong magnetic fields, or strong electrical signals.*

6.Do not open or disassemble the camera. There are no user-serviceable parts inside.

7.Do not drop the camera or subject it to strong vibrations.

Before Starting: Note: Many video monitors produce strong electromagnetic fields close to the display CRT, especially when the monitor is turned on or during de-gaussing, which occurs automatically with many monitors when the monitor is turned on.

Installation:

1.Run hidden cables from the video source and 12VDC power supply to the camera. Connect to the DC jack and female BNC connectors. Do not cut the DC jack or the female BNC connector as this will void the warranty. If needed, use the included SECO-LARM DC plug with terminal block.

2.Test to make sure the voltage is correct. Use only 12VDC.

3.Hold the camera against the wall, ceiling, or other mounting surface while watching the monitor to find the best mounting location. Mark that location

with a pencil.

4.Remove the dome from the camera by twisting it counterclockwise.

5.Remove the mounting base by releasing the latch indicated by white arrow on the inner rim of the camera.

6.If flush mounting, remove the punch-out in the base and run the wires through the center of the base.

7.Mount the mounting base by using the three included mounting screws to secure it to the wall. If the wall is made of drywall, brick, or similar material, it may be necessary to also use the three included screw anchors.

8.Secure the camera by lining it up with the base and turning the camera clockwise. To line up, make sure the gap in the mounting base is aligned with the wiring notch. The camera will click when locked into place.

9.Adjust camera angle as shown on page 2, Adjusting the Camera Angle.

10.Test the video signal.

11.Varifocal models only: Adjust the zoom and focus by hand or with a small screwdriver to loosen the knob, and then sliding the knob left or right. IMPORTANT: Do not use power tools. Lens damage may result.

12.Reattach the dome to the camera by giving the dome a slight twist. The dome will click when locked into place.

13.Do a final test of the video camera and monitor.

SECO-LARM U.S.A., Inc.