Installation:

ENFORCER Video, Power and Data Balun with Voltage Booster

Installation:

1. Run UTP cable to the camera where the VPD balun is being installed.

2.Remove the cover by simultaneously pressing down on the top cover, and lifting up on the side mounting tabs. This will release the tight seal between the top and bottom covers.

3.Set the desired output voltage using the selection jumper according to table 1 below.

4. Connect output wires from the power supply to the power input terminal blocks on the balun. Observe correct polarity

5.Apply power and use table 2 and 3 below to check the status of the input and output voltages.

NOTE: To avoid potential damage, use a voltage meter to ensure proper voltage is

present at the input and output terminal blocks. Observe correct polarity.

6. Connect the camera to the DC plug on the balun. If the output voltage is too low, then turn the rotary knob clockwise to increase the voltage or counter-clockwise to decrease the voltage.

7.Connect the video input male BNC input in from the VPD Balun to the camera.

8.If using a RS-485 controlled camera, connect the data in wires to the camera.

9.Using the input terminal blocks, connect data and video wires to the balun according to Figure 1.

IMPORTANT: Correct polarity must be observed on all connections.

10.Replace the cover on the voltage booster.

Table 1: Adjustable Output Voltage

Input Voltage

Output Voltage

Adjustable voltage range

Jumper Settings

7~12VDC

12VDC

12.5 ± 5%VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12~24VDC

24VDC

24.0 ± 10%VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 2: Wiring Distance 12 VDC Voltage Drop

24 AWG Wire

1 Pair

2 Pairs

3 Pairs

250mA

90'

220'

550'

500mA

45'

110'

285'

750mA

30'

75'

190'

1A

20'

55'

140'

Table 3: LED Indicators

LED colors

Status

Green

Power is connected

Red

Output is 12VDC

Blue

Output is 24VDC

NOTE: Chart is based on standard Cat5 24AWG wire and an allowable 10% voltage drop.

Figure 1: Sample Application

Power

Supply

 

SECO-LARM

Cat5 cable

 

Video Balun

 

DVR

PTZ

 

 

Controller

 

NOTE: To avoid potential damage, use a voltage meter to ensure proper voltage is present at the input and output terminal blocks. Observe correct polarity.

VDC out

Video in Table 1: Adjustable Output Voltage

Data out

Also Available from SECO-LARM:

Passive VGA Balun

Passive & Active

BNC-to-VGA

VPD Balun with

Video Baluns

Converter

Voltage Booster

 

EVT-SBP-GQ

EVT-PB1Q

VC-1BAQ

EVT-PB1-H05Q

 

(shown)

 

 

SECO-LARM U.S.A., Inc

3

Page 3
Image 3
SECO-LARM USA EVT-PB1-H05Q Installation, Sample Application, Also Available from SECO-LARM, Evt-Sbp-Gq, EVT-PB1Q, VC-1BAQ