Voltage Booster Efficiency Rate:

ENFORCER Video, Power and Data Balun with Voltage Booster

Voltage Booster Efficiency Rate:

The EVT-PB1-H05Q has a power efficiency rating of 85%. Under typical conditions, the booster will provide sufficient power to compensate for long cable runs. The following formulas can be used to determine if enough power is present at the power input of the voltage booster:

1.Calculate the amount of power measured in Watts: Voltage x Current = Power

2.For example, if the voltage is 12VDC, and the current is 750mA: 12VDC x .75 = 9 Watts

3.Then calculate the amount of power using the voltage booster with the following formula: Power Input x Efficiency Rate = Power Output.

4.Using the 9 Watts in the previous example, calculate power input of the booster:

9 Watts x .85 = 7.65 Watts

5.After the power has been calculated, the output current is calculated from the following formula: Power / Voltage = Current

6.Using the example of 9 watts present at the power input, and 7.65 Watts at the power output:

7.65Watts / 12VDC = 640mA of available current

Use Table 3 to determine if additional pairs of Cat5 cable will be needed to transmit power.

For more information see the Technical Bulletin for the ST-HB105-TTQ at www.seco-larm.com

Troubleshooting:

Output voltage is low/high

Check voltage jumper settings

 

Check output voltage adjustment.

 

Check input voltage to make sure it meets the input

 

requirements

Green input LED not on

Check input power connections with multimeter to verify

 

correct input voltage

Blue/red output LED not on

Check to see if the load exceeds the maximum limit

 

Temporarily disconnect power input and output wires for 30

 

seconds before connecting

WARRANTY This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.

This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship.

The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.

NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors. Copyright © 2008 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM.

SECO-LARM®U.S.A., Inc.

16842 Millikan Avenue, Irvine, CA 92606

Website: www.seco-larm.com

Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326

E-mail: sales@seco-larm.com

PITSW4

mi-EVT-PB1-H05Q.docx

4

SECO-LARM U.S.A., Inc.

Page 4
Image 4
SECO-LARM USA EVT-PB1-H05Q Voltage Booster Efficiency Rate, Troubleshooting, SECO-LARM U.S.A., Inc, SECO-LARMU.S.A., Inc