INSTALLER PROGRAMMING

Digital Access Keypad Manual

INSTALLER PROGRAMMING

These functions should only be used by professional installers, as incorrect entries can disable the entire keypad function.

Enter Programming Mode

 

 

(DEFAULT: 0 0 0 0 )

Enter Master code

Confirm

 

Function

X X X X *

 

*

 

 

Enter into programming mode

*Key in the Master Code.

 

 

 

Note: For first-time use, Master code is

0 0

0 0

 

 

 

 

 

Data Refresh

 

 

 

 

Option

 

Confirm

Function

 

 

 

8

9 0

1

#

Clears all previously stored data.

 

 

 

 

Configure Relay Outputs

 

 

(DEFAULT: Momentary, 1-sec. output)

Option

Output time

Confirm

Function

4

0

1 to 999

#

 

Relay momentary mode, from 1 to 999 seconds

4

1

 

 

#

 

Relay shunt mode (ON/OFF)

 

 

Relay Output Inhibit Control (lockout mode)

(DEFAULT: Momentary, 1-sec. output)

Option

Code Entry

Confirm

Function

5

0

1 to 999

#

 

Lockout for 1 to 999 seconds

5

1

 

 

#

 

Lockout shunt mode (ON/OFF)

 

 

 

 

 

Wrong Code Lockout

 

 

 

(DEFAULT: 10 tries / 30 seconds)

Option

 

# of tries

Confirm

Function

 

7

0

 

 

 

After 10 successive wrong codes, 30-second lockout

7

1

 

 

 

After 10 successive wrong codes, Duress activated

7

2

 

5 to 10

#

After 5 to 10 wrong codes, 15-min. lockout - Can reset with Master Code

7

6 0

0

 

#

None of the above

 

 

 

 

Output Activation Announcer

 

 

(DEFAULT: On)

Option

Code entry

Confirm

Function

 

 

 

{

1

#

1-sec. beep notifies the user to open the door when the output relay is activated with the

8

1

 

 

user code or egress button. Use with a locking device which gives no sound when it

 

 

activates, such as a magnetic lock.

 

 

 

 

 

 

0

#

The beep is disabled, replaced by 2 short beeps for valid user codes.

 

 

 

 

 

User Code Entry Mode

 

 

 

(DEFAULT: Manual)

Option

Code entry

Confirm

Function

 

 

 

{

1

#

Auto Entry Mode is selected. The # key that follows the user code is NOT required in

8

2

 

 

code entry. The User Codes MUST be set to the same digit length as the Master Code,

 

 

from 4-8 digits.

 

 

 

 

 

 

0

#

Manual Entry Mode is selected. The # key that follows the user code is required in

 

 

 

 

 

code entry. The User Codes can be 4-8 digits, but not necessarily all of the same length.

 

 

 

 

 

Keypress Beeps

 

 

 

(DEFAULT: On)

Option

Code entry

Confirm

Function

 

8

3

{

1

#

Keypad beeps when a key is pressed.

0

 

Silent operation -- keypad does not beep when a key is pressed.

 

 

#

 

 

 

 

 

 

 

 

Exit Programming Mode

Confirm Function

*Exits programming mode, returns keypad to normal operations

USER CODE WORKSHEET

To print out a blank worksheet where all user codes can be recorded, please visit www.seco-larm.com and select the Model #, "SK-1011-SQ" in the drop down menu for the burglar section. On the product page click on "User Code Worksheet," which will load the .PDF.

Digital Access Keypad Manual

SPECIFICATIONS:

Power:

Operation voltage -- 12-24 Volts AC/DC. No jumper needed to set voltage.

Stand-by current drain -- 10mA @12VDC.

Active current drain (press keypad key) -- Under 30mA.

Active current drain (relay activated) -- Under 80mA.

Outputs:

Relay output -- 5A @ 28VDC, Form "C", N.O./C./N.C., programmable for 1 to 999 second timed output or shunt (start/stop) output. Three terminals.

Tamper output -- N.C. output. Connect to tamper circuit of alarm control panel. Two terminals.

Inputs:

Power -- 12-24Volts AC/DC. Two terminals.

Egress -- N.O., ground (-). Single terminal.

Code Operation:

Up to 100 user codes, 10,000 possible user code combinations.

Max. 10 seconds to enter each digit.

Max. 30 seconds to enter each code.

Dimensions (keypad with back box):

4-5/8" x 2-7/8" x 1-7/8" (117 x 74 x 48 mm).

Weight (keypad with back box):

6.3 oz. (180 grams).

WIRING (SAMPLE INSTALLATION):

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tamper

 

(+) (--)

 

OUTPUT 1

EG

 

N.C.

 

12~24V AC/DC

 

N.C.

C. N.O.

 

Connect to the N.C.

 

 

 

 

 

(+)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24hr. zone of alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

panel or other

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

signalling device.

 

 

 

 

 

N.C.

 

N.O.

 

 

 

 

 

 

 

 

 

 

 

 

 

OR

 

 

 

 

 

 

 

 

 

 

 

 

 

+

--

 

Electric

 

 

 

 

 

12VDC

+

Lock

--

 

power

 

 

 

 

supply

 

 

 

 

(for DC

 

REMARKS:

 

Diode

 

Output relay

 

use only)

 

N.O. output for fail-secure lock.

1N4004

 

 

N.C. output for fail-safe lock.

Cathode

 

 

 

Additional egress buttons

Egress button (inside the

 

 

N.O.

N.O.

can be connected in parallel

protected premises)

as needed

 

 