SECO-LARM USA SK-910RC4Q manual Setting the Timed Output, Setting the Auxiliary Relay

Models: SK-910RC4Q

1 8
Download 8 pages 29.55 Kb
Page 6
Image 6
*Note
Included power supply will not
support loads larger than 500mA.
For larger loads, replace with appropriate DC power supply.

ENFORCER SK-910RC4Q Central Receiver

Setting the Timed Output:

When a channel is set to Timed Output, triggering the channel will activate the relay for a set period of time. Factory default is 1 second.

1. The time can be set from 1~60 seconds using the Timer switches on the top of the receiver.

2. Set switches according to the following chart.

NOTE: The time set via the DIP switches applies to all channels programmed for Timed Output.

Sec.

SW1

SW2

SW3

 

 

 

Top of unit

1*

On

Off

Off

 

 

 

 

 

 

 

2

Off

On

Off

Timer switches

3

Off

Off

On

 

 

 

 

4

On

Off

On

 

 

 

 

 

 

 

 

5

Off

On

On

 

 

 

 

 

 

 

 

10

On

On

Off

 

 

 

 

30

Off

Off

Off

SW1 SW2 SW3

60

On

On

On

 

 

 

 

*Default setting

Setting the Auxiliary Relay:

Each channel may be individually set to activate a separately timed 12VDC output programmable from 1 second to 10 minutes. The auxiliary relay provides up to 3A@12VDC*.

1.Connect the auxiliary device to the auxiliary relay. The two auxiliary relay terminals are the left-most terminals on the terminal block as shown in the diagram below.

2.Select which channels will trigger the auxiliary relay using the Auxiliary Relay DIP switch (SW8), located on the PCB as shown in the diagram below.

3.If the switch is in the ON position, triggering the

corresponding channel will activate the auxiliary relay.

4. If the switch is in the OFF position, triggering the corresponding channel will not activate the auxiliary relay.

Setting Auxiliary Relay Timer:

1.Output time can be adjusted from 1 second to 10 minutes using the auxiliary relay output time potentiometer.

2.Turning the potentiometer clockwise will increase the output time.

3.Turning the potentiometer counterclockwise will decrease the output time. Auxiliary relay time potentiometer

PCB

Use the DIP switch to select the channel. Default is Channel 1 ON.

Terminal Block Auxiliary relay terminals

6

SECO-LARM U.S.A., Inc.

Page 6
Image 6
SECO-LARM USA SK-910RC4Q manual Setting the Timed Output, Setting the Auxiliary Relay, Setting Auxiliary Relay Timer