1. Connecting the headset to the on-board system

Power supply for

NoiseGard™

Ground

Manual backgroundManual backgroundManual backgroundManual background Do not connect !

XLR-3 socket

1. Connecting the headset to the on-board system

The NoiseGard™ electronics can be connected to on-board power supply systems with operating voltages between 12–35 V DC.

Danger of short circuit!

Before turning on NoiseGard™, ensure that the on-board power supply system is protected by a 1 A fuse.

The HMEC 350, HMEC 355-C, HMEC 372, HMEC 450 and HMDC 372 headsets are supplied with an XLR-3 socket for panel mounting in the aircraft. The XLR-3 socket must be mounted by a technician qualified to perform this type of installation.

HMEC 350 and HMEC 450 headsets:

￿Connect the ¼” (6.35 mm) stereo jack plug for the headphones and the PJ-068 jack plug for the microphone to the corresponding jack sockets of your intercom.

￿Connect the XLR-3 plug to the XLR-3 socket.