Sennheiser SK 500 Operating menu of the transmitter, Exit, Name, 1.03, Bank U, Tune, Sensit

Models: EK 500 SK 500

1 31
Download 31 pages 16.41 Kb
Page 18
Image 18
Operating menu of the transmitter

Operating menu of the transmitter

SET

EXIT

 

 

 

 

 

SET

 

 

 

 

 

 

 

 

 

 

BANK

 

 

BANK 1

 

 

 

 

BANK U

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Changing the channel

 

 

 

 

Current channel bank

 

 

 

/ : 1...8, U (User

 

 

bank

 

 

 

 

 

 

 

 

 

Bank)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SET: Stores the setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STORED

 

 

 

 

 

 

 

 

 

 

 

SET

 

 

 

 

 

 

 

 

 

 

CHAN

 

 

 

1.03

B.CH

 

 

 

1.02 B.CH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Changing the channel

 

 

 

 

Current channel

 

 

 

 

/ : Channel 01...20

 

 

 

 

 

 

 

 

 

(display depends on

 

 

 

SET: Stores the setting

 

 

 

 

 

 

 

 

 

"DISPLY" setting)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STORED

 

 

 

 

 

 

 

 

 

 

 

SET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TUNE

 

790.025 MHz

 

 

 

791.125 MHz

 

 

 

 

 

 

 

 

 

 

 

Setting the frequency

 

 

 

 

Current frequency on

 

 

 

/ : Transmission

 

 

for channel bank "U"

 

 

 

 

the selected channel

 

 

 

frequency in steps of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25 kHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SET: Stores the setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STORED

 

 

 

 

 

 

 

 

 

 

 

SET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SENSIT

 

 

 

-10dB

 

 

 

 

-30dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting the sensitivity

 

 

 

 

Current sensitivity

 

 

 

 

/ : 0...-30 dB

 

 

 

 

 

 

 

 

 

setting

 

 

 

 

SET: Stores the setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STORED

 

 

 

 

 

 

 

 

 

 

 

SET

 

 

 

 

 

 

 

 

 

 

DISPLY

 

 

FREQ

 

 

 

 

NAME

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Switching between the

 

 

 

 

Current standard display

 

 

 

/ : FREQ, NAME,

 

 

standard displays

 

 

 

 

 

 

 

 

 

CHAN

 

SET: Stores the setting
STORED

NAME

18

Page 18
Image 18
Sennheiser SK 500 Operating menu of the transmitter, Exit, Name, 1.03, Bank U, Tune, Sensit, 30 dB, Freq, Stored, Chan