ew500_SKM.book Seite 43 Mittwoch, 5. November 2003 9:13 09

Push the battery compartment into the radiomicrophone’s body.

Screw the display section tight.

Note:

For accupack operation of the radiomicrophone, only use the BA 2015 accupack in order to ensure optimum operational reliability. For charging the accupack, only use the L 2015 charger. Both the accupack and the charger are available as accessories.

The accupack is fitted with an integrated sensor which is

via a third contact – monitored by the electronics of the radiomicrophone and the charger. The sensor is necessary for the following control purposes:

y The taking into account of the different voltage characteristics of primary cells (batteries) and accupacks. The battery status indications on the displays, the transmission of transmitter battery status information to the rack-mount receivers and the switch-off thresholds at the end of the operating time are corrected correspondingly. Due to the missing sensor, individual rechargeable battery cells will not be identified as accupacks.

y The monitoring of the accupack temperature during charging in the L 2015 charger.

Changing the microphone head

First remove the batteries/accupack as described above and leave the radiomicrophone open.

Unscrew the sound inlet basket.

Loosen the screw and put it to one side.

43