Sensoray Model 7405 Instruction Manual — Page 3
Hardware Configuration
The Model 7405 requires the installation of programming
shunts to select various options such as I/O port addresses
and channel operating modes. This section describes these
configuration options.
After configuring the option shunts, the Model 7405 may be
installed in your STDbus backplane and programmed as
explained in the Programming section of this manual.
Both board address and channel output types are established
by installing programming shunts at various locations on the
board. In all of the following discussions of shunt
programming, I denotes an installed programming shunt and
R indicates that no shunt is installed:

Defaults

All option jumpers are set to a standard default configuration
at the factory. If the default configuration is consistent with
your application, you may be able to use the board without
having to reconfigure any jumpers.

I/O Space

Two separate I/O spaces exist on the STDbus: primary and
expanded. Option jumper E8 selects which I/O space the
Model 7405 board will reside in. E8 is factory set to map the
board into primary space.

I/O Port Mapping

The Model 7405 occupies two consecutive 8-bit addresses in
the selected STDbus I/O address space. These ports may be
mapped to any even address from 0x00 to 0xFE. Jumpers
are factory installed to locate the board at ports 0xB2 and
0xB3.
The following tables show the jumper configurations for all
possible board addresses. Use the table on the left for the
most significant address nibble, and the table on the right for
the least significant address nibble.

Channel Mode

Each channel has three mode control option jumpers, used to
select either voltage or current output mode. A channel’s
mode control jumpers work as a set. For any given channel,
either all jumpers should be installed or all should be
removed. A jumper set should be installed to configure the
associated channel for current output. Conversely, the
jumper set should be removed to configure the channel for
voltage output.
For example, jumpers A3, B3 and D3 must all be installed to
configure channel 3 for the 4-20mA current output mode.
Jumpers A7, B7 and D7 must all be removed to configure
channel 7 for the ±10 volt output mode.
Programming
Programming of the Model 7405 is accomplished by means
of three STDbus interface registers. One register is used to
let the host processor know when new data may be sent to
the board. The other two registers receive a combination of
channel number and analog channel data from the host.
Symbol Meaning
IShunt installed
RShunt removed
Attribute Default
I/O base address 0xB2
I/O Space Primary
Analog channel mode Voltage out
E8 I/O Address Space
IPrimary
RExpanded
E7 E6 E5 E4 Val E3 E2 E1 Val
I I I I 0I I I 0
I I I R1I I R2
I I RI2IRI4
I I R R 3IR R 6
IRI I 4RI I 8
IRIR5RIRA
IR R I6R R IC
IR R R 7R R R E
RIII8
RI I R9
RIRIA
RIR R B
R R IIC
R R IRD
R R R IE
R R R R F
Channel Jumper Set
0A0 B0 D0
1A1 B1 D1
2A2 B2 D2
3A3 B3 D3
4A4 B4 D4
5A5 B5 D5
6A6 B6 D6
7A7 B7 D7