Sentry : Solutions for the Data Center Equipment Cabinet

Key Features

>High Density: Single-power input feed; 24 outlets per enclosure

>High Power Distribution: Three-Phase 400V power; 16 or 32-Amp power input feed options with 230V output

>Input Current Monitor: Precisely measure the aggregate current draw (in amps) on each power circuit. On-site verification of the input current with the LED digital display. Remote verification via web browser or serial screen.

>IP Access & Security: Web interface, SSL, SSH, Telnet, SNMP, FTP, SNTP, Syslog, LDAP, LDAPS, TACACS and RS-232 access

>SNMP Traps: Provide automated alerts for power and environmental conditions

>Power-up Sequencing: Prevent an in-rush power overload

>Environmental Monitoring: Each Switched CDU supports two external temperature & humidity probes and reports conditions thru the user interface without the need for additional IP addresses

>Add an Expansion Module: Daisy chain the Switched CDU Expansion Module (CW/CX) for power monitoring of separate power circuits from a single IP address

Sentry Switched CDU

CW-24V4

High Density Power Distribution

The Switched CDU’s combine remote configuration and management with power distribution and power and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP or email based alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups.

Only the Switched CDU products provide the flexibility needed for all data centers and remote sites, including power requirements for high-amp, high voltage; UL 60950-1 branch circuit protection; SSL & SSH security; and SNMP-based input current monitoring.

Additional Benefits:

Branch Circuit Protection

The Sentry CDU Family meets the UL 60950-1 requirement for Branch Circuit Protections

> UL-489 rated circuit breakers

Input Current Monitoring

Exclusive True RMS current monitoring is critical to preventing overloads in high-density computing environments. LED digital displays on the CDU enclosure report the input current of each phase or branch circuit.

Temperature and Humidity

The Switched CDU supports two external 10’ (3m) probes. Each of these probes measure both temperature and humidity. Receive SNMP-based alerts or email notifications when conditions exceed defined thresholds.

Page 1
Image 1
Server Technology CDUCW-24V4 specifications Branch Circuit Protection, Input Current Monitoring, Temperature and Humidity