OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
Attaching the Shoulder Strap
Using the detachable shoulder strap allows for greater freedom of movement when both hands are needed for various cleaning tasks. To attach the shoulder strap to the steam cleaner, simply snap the shoulder strap hooks onto the connecting rings on the unit body. (Fig. 12)
Connecting | Connecting | |
points | ||
points | ||
|
Fig. 12
Using Your Steam Cleaner
After you have assembled the steam cleaner and are ready to use:
1.When you press the steam trigger it will lock in place and you will have continuous steam.
2.To stop the flow of steam, press the steam trigger release button.
3.When using the unit with the shoulder strap, avoid rocking or tilting the unit excessively as this may cause water to enter the hoes and be discharged along with the steam.
Components
Indicator Lights: The steam cleaner has an indicator light located at the base of the unit that will illuminate when the unit is plugged into the 120V wall outlet.
Red Light: When the red indicator light illuminates, this indicates that the power is “On”.
Green Light: When the green indicator light illuminates, the steam is ready. CAUTION: Read the instructions for “Filling or Refilling Your Steam Cleaner with Water” before opening the safety filler cap.
CAUTION: Always unplug before filling.
ALLOW UNIT TO COOL FOR FIFTEEN
(15)MINUTES BEFORE REFILLING. IMPORTANT: Do NOT add cleaning solutions, scented perfumes, oils or any other chemicals to the boiler in this appliance. Use tap water or distilled/purified water if the tap water in your area is very hard.
Filling or Refilling Your Steam Cleaner With Water
IMPORTANT: Always insure that the unit is “UNPLUGGED” from the wall receptacle prior to initial filling or
Fig. 1
WARNING: Extreme care should be taken when refilling the unit. Allow unit to cool for15 minutes before refilling. When refilling the steam cleaner while the boiler is still hot, there is a risk that water will squirt back during filling and cause scalding. Use caution when opening the filler cap as the cap may become hot during use and escaping steam can cause scalding.
5.To attach the concentrator nozzle or the steam/garment diffuser to the nozzle: align the two pins on the end of the concentrator nozzle or steam/garment diffuser with the notches in the nozzle of the unit. (Fig. 2)
IMPORTANT: When using the steam cleaner with the shoulder strap, avoid rocking or tilting the unit excessively as this may cause water to enter the hose and be discharged
tank and has been allowed to cool. Never attempt to fill this unit under a water tap, always use the measuring cup and funnel provided.
1. Before filling or refilling the steam |
Steam/Garment
Diffuser
Fig. 2
Unit
Nozzle
along with the steam.
| cleaner, make sure that the unit is NOT |
| plugged in and has been allowed to cool |
| for fifteen (15) minutes. |
2. | Press the locking steam trigger on the |
| handle of the unit to vent any residual |
| steam that is in the boiler. |
3. | Place the unit on a flat, stable surface. |
| Slowly, press and turn the filler cap |
| counter clockwise until it is removed. |
4. | Place the funnel in the tank opening. |
| (Fig. 1) Fill with a maximum of one filling |
| flask or 9.5 oz (280 ml) of water. Do Not |
| Overfill. Turn the safety cap clockwise |
to replace.
NOTE: To remove or replace the filler cap, push down and rotate it clockwise to tighten or counter
NOTE: Filling the unit with hot water will shorten the heat up time.
6.Push the attachment into the nozzle unit it stops against the unit. Turn clockwise ¼ turn to lock the attachment into place. Allow approximately 5 minutes for vapor to reach its working temperature and pressure. When the unit is ready for use, the green indicator light will illuminate. Always point the nozzle in a safe direction. At the start, some
water will come out from the nozzle. This is normal.
NOTE: When the steam cleaner has run out of water, steam output will cease. CAUTION: This appliance is under pressure. After every use, press steam trigger button until all pressure has been released before removing safety cap. Allow unit to cool for fifteen (15) minutes before refilling.
8
5