72GF-66E

DESCRIPTION OF SCHEMATIC DIAGRAM

SAFETY NOTE:

1.DISCONNECT THE AC PLUG FROM THE AC OUTLET BEFORE REPLACING PARTS.

2.SEMICONDUCTOR HEAT SINKS SHOULD BE REGARDED AS POTENTIAL SHOCK HAZARDS WHEN THE CHASSIS IS OPERATING.

IMPORTANT SAFETY NOTE:

 

PARTS MARKED WITH « ! » (

) ARE

IMPORTANT FOR MAINTAINING THE SAFETY OF THE SET. BE SURE TO REPLACE THESE PARTS WITH SPECIFIED ONES FOR MAINTAIN- ING THE SAFETY AND PERFORMANCE OF THE SET.

SERVICE PRECAUTION:

THE AREA ENCLOSED BY THIS LINE () IS DIRECTLY CONNECTED WITH AC MAINS VOLTAGE.

WHEN SERVICING THE AREA, CONNECT AN ISOLATING TRANSFORMER BETWEEN TV RECEIVER AND AC LINE TO ELIMINATE HAZ- ARD OF ELECTRIC SHOCK.

WAVEFORM MEASUREMENT CONDITION: Colour bar generator signal of 70 dB from RF input.

1

2

GND

GND

580V

1.3 KV 31.25 KHz

5

6

GND

 

NOTE:

1.The unit of resistance «ohm»is omitted (K=1000 ohms. M= Megaohm).

2.All resistors are 1/8 watt. unless otherwise noted.

3.All capacitors are mF, unless otherwise noted (P= mmF).

4.The capacitor with Part No. RC-FZ9XXXBMNJ is designed to with stand 63V.

5.The capacitor with Part No. RC-FZ4XXXBMNJ is designed to with stand 50V.

CAUTION

This circuit diagram is original one, therefore there may be light difference from yours.

3

4

GND

GND

 

4 Vp-p 31.25 KHz

350 Vp-p 100Hz

7

8

41 Vp-p 31.25 KHz

1.8 Vp-p 100Hz

3.3V 100Hz

45 Vp-p 113 KHz FM

9

10

 

 

11

12

19Vp-p 100Hz

GND

 

25 Vp-p 100Hz

1.15 Vp-p 31.25KHz

400Hz

 

 

 

13

 

 

 

 

 

400Hz

27

Page 27
Image 27
Sharp 72GF-66E service manual Description of Schematic Diagram