Sharp AE-X12LCJ, AY-X18LCJ, AY-X09LCJ Specifications, Air Flow Volume m3/h, Model of Indoor Unit

Models: AE-X09LCJ AE-X18LCJ AE-X12LCJ AY-X12LCJ AY-X09LCJ AY-X18LCJ

1 36
Download 36 pages 62.21 Kb
Page 27
Image 27
Specifications

Specifications

Model

 

AY-X09LCJ; AE-X09LCJ

Function

 

Cooling

 

Heating

Rated Voltage (V)

220-240

 

 

 

 

 

Frequency (Hz)

50

 

 

 

 

 

 

Total Capacity (W) (High/Standard):

2600/1188

 

2805/1109

Total Capacity (Btu/h) (High/Standard):

9000/4063

 

9800/3792

 

 

 

 

 

Power Input (W) (High/ Standard/Low):

1200/610/264

 

1250/670/230

 

 

 

 

 

Rated Input (W)

610

 

670

 

 

 

 

 

Rated Current (A)

5.5

 

6

 

 

 

 

 

Air Flow Volume (m3/h)

450

 

Dehumidifying Volume (l/h)

0.8

 

 

 

 

 

 

EER / C.O.P (W/W)

4.25

 

4.22

 

 

 

 

 

Energy Class

A/A

 

 

 

 

 

 

Model of Indoor Unit

AY-X09LCJ

 

 

 

 

 

 

Fan Motor Speed (r/min) (H/M/L)

1100/950/820

 

 

 

 

 

 

Output of Fan Motor (W)

10

 

 

 

 

 

 

Fan Type-Piece

Cross flow fan – 1

 

 

 

 

 

 

Diameter-Length (mm)

φ85 X 668

 

 

 

 

 

Evaporator

Aluminum fin-copper tube

 

 

 

 

 

Pipe Diameter (mm)

φ7

 

 

 

 

 

 

Row-Fin Gap(mm)

2-1.5

 

 

 

 

 

Indoor

Coil length (l) x height (H) x coil width

657X285X25.4

 

Unit

(L)

 

 

 

 

Swing Motor Model

MP28VB

 

 

 

 

 

 

 

Output of Swing Motor (W)

2

 

 

 

Fuse (A)

PCB 3.15A Transformer 0.2A

 

 

 

 

 

 

Sound Pressure Level dB (A)

42/38/30/28

 

 

(S/H/M/L)

 

 

 

 

 

 

Sound Power Level dB (A) (S/H/M/L)

53/47/40/38

 

 

 

 

 

 

Dimension (W/D/H)( mm)

872X178X283

 

 

Dimension of Package (W/D/H)( mm)

935x260X375

 

 

 

 

 

 

Net Weight /Gross Weight (kg)

12/15

 

 

 

 

 

 