Sharp AE-X18LCJ, AY-X18LCJ, AY-X09LCJ, AY-X12LCJ Outdoor unit, Model of Outdoor Unit, m3/h

Models: AE-X09LCJ AE-X18LCJ AE-X12LCJ AY-X12LCJ AY-X09LCJ AY-X18LCJ

1 36
Download 36 pages 62.21 Kb
Page 28
Image 28
Outdoor unit

Outdoor unit

Model of Outdoor Unit

AE-X09LCJ

Compressor

SANYO

Manufacturer/trademark

 

Compressor Model

C-6RZ110H1A

Compressor Type

Twin rotary

L.R.A. (A)

33

Compressor RLA(A)

4.59

Compressor Power Input(W)

800

Overload Protector

Int11l-3979

Throttling Method

Capillary throttling

Starting Method

Transducer starting

Working Temp Range ()

-7℃≤T43

Condenser

Aluminum fin-copper tube

Pipe Diameter (mm)

9.52

Rows-Fin Gap(mm)

2-1.4

Coil length (l) x height (H) x coil

608X508X44

width (L)

 

Fan Motor Speed (rpm)

830±20

Output of Fan Motor (W)

30

Air Flow Volume of Outdoor Unit

1800

(m3/h)

Fan Type-Piece

Axial fan –1

Fan Diameter (mm)

400

Defrosting Method

Auto defrost

Climate Type

T1

Isolation

I

Moisture Protection

IP24

Permissible Excessive Operating

 

Pressure for the Discharge

3.8

Side(MPa)

 

Permissible Excessive Operating

1.2

Pressure for the Suction Side(MPa)

 

Sound Pressure Level dB (A)

54

(H/M/L)

 

Sound Power Level dB (A) (H/M/L)

64

Dimension (W/D/H)( mm)

848X320X540

Dimension of Package

878X360X590

(W/D/H)( mm)

 

Net Weight /Gross Weight (kg)

40/45

Refrigerant Gas & Charge (kg)

R410A / 1.1

-25-