POWER CONNECTIONS

This appliance is manufactured with a neutral (white) power supply wire and a cabinet-connected green grounding wire.

Connect the appliance cable to the junction box through the UL- listed conduit connector. Complete electrical connection according to local codes and ordinances. For preferred junction box location, see Figure 2, page 2.

INSTALLATION MANUAL

3-WIRE CONNECTION

When local codes permit connecting the cabinet-grounding conductor to the neutral (white) wire.

1Disconnect the power supply.

2In the junction box connect the appliance and residence cable wires as shown in Figure 18.

NOTE TO ELECTRICIAN: The armored cable leads supplied with this appliance are UL recognized for connection to larger gauge household wiring. The installation of the leads is rated at temperatures much higher than the temperature rating of household wiring. The current carrying capacity of the conductor is governed by the temperature rating of the installation around the wire, rather than the wire gauge alone.

Improper connection of aluminum house wiring to copper leads can result in an electrical hazard or fire. Use only connectors designed for joining copper to aluminum and follow manufacturer’s recommended procedure closely.

GENERAL NOTE FOR WIRE NUT APPLICATIONS: The proper size wire nut shall be placed over the stripped leads and the wire nut twisted until the wire nut can not be pulled from the leads. No conductor shall be exposed in the connection.

Conduit connector (not supplied)

Appliance conduit & wires

Green wire (ground)

Figure 18

Black wires

Red wires

Power supply

White wires (nutral)

4-WIRE CONNECTION

When installing to a 4-wire electrical system, new construction, mobile home and recreational vehicle or when local codes do not permit grounding through neutral.

1Disconnect the power supply.

2In the junction box connect the appliance and residence cable wires as shown in Figure 17.

 

Red wires

Green wires

 

Conduit connector

 

(not supplied)

 

Appliance

Power supply

conduit & wires

 

 

White wires (nutral)

 

Black wires

Figure 17

REINSTALL JUNCTION BOX COVER

Do not shorten the flexible conduit. The conduit strain relief clamp (supplied by installer) must be securely attached to the junction box and the flexible conduit must be securely attached to the clamp. If the flexible conduit will not fit with the junction box, do not install the appliance until a clamp of proper size has been obtained.