ENGLISH
DRAINAGE
Prepare for drainage and drain out water within the unit in the following cases.
If the unit stops operating and the TIMER, OPERATION and MEGA COOL lamps are
blinking. (This indicates that the water tank inside the unit is full.)
1Make sure to turn the unit off.
2Turn the drainage nozzle to the OPEN
position.
3Pull the stopcock out from the drainage
nozzle.
When the stopcock is removed, a small amount of
water may be discharged from the drainage nozzle.
4Insert the hose clamp into a standard
commercially available hose (5/8" inner
diameter, 7/8" outer diameter) and attach
the drain gromment to the hose.
5Attach the hose to the drainage nozzle, and
secure it with the hose clamp.
Prepare for draining, as drain water will come out
through the hose during operation.
6Press the AUX. button on the unit twice.
The water will drain out through the drainage hose.
Maximum amount of water that may be drained
out is approximately 41/5 pints.
The OPERATION, TIMER and MEGA COOL
lamps will be blinking.
7When drainage water stops running out from the hose, turn the unit off by
pressing AUX. button.
This would take about one minute.
8Remove the hose from the drainage nozzle, and replace the stopcock.
Keep the hose clamp and drain grommet in case of re-used.
9Turn the drainage nozzle to the CLOSE position.
Whenever the unit is moved (to provent water within the unit from spilling).
When the unit is not used for a long time.
1Carry out the above procedures from 1 to 5.
2Press the AUX. button on the unit.
The water will drain out through the drainage hose.
Maximum amount of water that may be drained out is approximately 41/5 pints.
The OPERATION lamps will light.
3When drainage water stops running out from the hose, turn the unit off by
pressing AUX. button.
This would take about one minute.
4Remove the hose from the drainage nozzle, and replace the stopcock.
Keep the hose clamp and drain grommet in case of re-used.
5Turn the drainage nozzle to the CLOSE position.
6Remove the stopcock from the drainpipe nozzle, and completely drain any
water within the unit.
Always prepare a receptacle to collect the water
before draining. Maximum amount of water that
may be drained out is approximately 2/5 pints.
7Replace the stopcock to the drainpipe nozzle.
E-29
Stopcock
Drainpipe nozzle
Drainage
nozzle
Stopcock
Drain grommet
"OPEN" position
Hose clamp
Hose