Sharp FU-Y30J-W Specifications, The class of the HEPA filter by EN 1822 is H10, E-12

Models: FU-Y30J-W

1 16
Download 16 pages 11.88 Kb
Page 14
Image 14
SPECIFICATIONS

SPECIFICATIONS

 

Model

 

 

FU-Y30J-W

 

 

Power supply

 

220-240V 50/60Hz

 

Fan

Fan Speed Adjustment

MAX

 

MED

LOW

Speed

Rated Power

49W

 

32W

23W

Operation

Fan Speed

180m3/hour

 

120m3/hour

60m3/hour

 

Recommended Room Size

 

 

~21m2 *1

 

High density Plasmacluster ion recommended room size

 

 

~13m2 *2

 

 

Cord Length

 

 

2.0m

 

 

Dimensions

356mm(W)x180mm(D)x510mm(H)

 

Weight

 

 

5.0kg

 

*1 Size of a room which is appropriate for operating the unit at maximum fan speed.

•It indicates the space where a certain amount of dust particles can be removed in 30 minutes(JEM1467).

*2 Size of a room in which approximately 7000 ions can be measured per cubic centimeter in the center of the room (at a height of approximately 1.2 meters from the floor) when the product is placed next to a wall and run at the MAX operation position.

Standby Power In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this product consumes about 1.0W of standby power.

For energy saving, unplug the power cord when the unit is not in use.

The class of the HEPA filter by EN 1822 is H10.