PREPARE THE HOOD

Non-Ducted Installations Only:

Requires a Performance Ring to be attached to the blower wheel. The Performance Ring is packed behind the Teflon®- Coated Bottom Cover.

To install ring:

1.Remove Retaining Ring using a flat blade screwdriver. Set aside for later. Remove the Blower Wheel by rocking it side to side and applying a slight force to pull wheel from motor. Turn the Blower Wheel over.

2. Slide the Performance Ring onto the Small Diameter End of the blower wheel and down to the Stop Edge of the wheel.

3.Reassemble wheel to motor. Make sure Tab on wheel fits into one of the Motor Slots.

4. Push wheel down until it is locked in place. Replace Retaining Ring from Step 1. Be sure it is within the upper and lower tabs.

5.Check that wheel is properly positioned as shown. Press Sections into place if necessary. Make sure wheel turns freely.

Note: For information on non-ducted filters, see page 9.

RETAINING RING

BLOWER

SMALL DIAMETER

WHEEL

END

 

TAB

 

SECTIONS

STOP

EDGE

MOTOR SLOTS PERFORMANCE RING

CONNECT WIRING

WARNING To reduce the risk of electric shock, make sure power is switched off at the service panel. Lock or tag service panel to prevent power from being switched on accidentally.

1Connect House Wiring (120 VAC) to hood. Use a piece of cardboard to protect the cooktop, if necessary.

2Connect house black to hood black wire, house white to hood white wire and house ground under Green Ground Screw. Securely tighten cable clamp onto house wiring.

8