Setting up the Projector Using RS-232C or Telnet

SETUP MENU (Main Menu)

SETUP MENU

---------------------------------

SETUP MENU--------------------------------

 

 

[1]IP Address

[2]Subnet Mask

[3]Default Gateway

[4]User Name

[5]Password

 

[6]RS-232C Baud Rate

[7]Projector Name

[8]DHCP Client

[A]Advanced Setup

 

[D]Disconnect All

[V]View All Setting

[S]Save & Quit

[Q]Quit Unchanged

setup>

 

 

 

 

 

[1]IP Address

IP address settings. (Page 23)

[2]Subnet Mask

Subnet mask settings. (Page 23)

[3]Default Gateway

Default gateway settings. (Page 23)

[4]User Name (Factory default setting : Not Re- quired)

Setting of user name for security protection. (Page 23)

[5]Password (Factory default setting : Not Required)

Setting of password for security protection. (Page 24)

[6]RS-232C Baud Rate (Factory default setting : 9600 bps)

Baud rate settings for the RS-232C terminals. (Page

24)

[7]Projector Name

It is possible to assign a projector name. (Page 24)

[8]DHCP Client

DHCP Client settings. (Page 24)

[A]Advanced Setup

Enters ADVANCED SETUP MENU. (Page 25)

[D]Disconnect All

Disconnect all connections. (Page 25)

[V]View All Setting

Displays all setting values. (Page 21)

Can also be used with ADVANCED SETUP MENU.

[S]Save & Quit

Save set values and quit menu. (Page 22)

[Q]Quit Unchanged

Quit menu without saving setting values. (Page 22)

ADVANCED SETUP MENU

ADVANCED SETUP MENU

******************** ADVANCED SETUP MENU ***********************

[1]Auto Logout Time

[2]Data Port

[5]Network Ping Test

 

[6]Accept IP Addr(1)

[7]Accept IP Addr(2) [8]Accept IP Addr(3)

[9]Accept All IP Addr

[0]Search Port

[!]Restore Default Setting [Q]Return to Main Menu

advanced>

[1]Auto LogoutTime (Factory default setting : 5 min- utes)

Setting of time until automatic disconnection of network connection. (Page 25)

[2]Data Port (Factory default setting : 10002)

Setting the TCP port number used when exchanging data. (Page 25)

[5]Network Ping Test

It is possible to confirm that a network connection between the projector and a computer etc. is working normally. (Page 26)

[6]Accept IP Addr(1) [7]Accept IP Addr(2) [8]Accept IP Addr(3)

[9]Accept All IP Addr (Factory default setting : Accept All)

For improved security, it is possible to set up to three IP addresses allowing connection to the projector. Set IP addresses can be cancelled using [9] Accept All IP Addr. (Page 26)

[0]Search Port (Factory default setting : 5006) Setting the port number used when searching for the projector. (Page 27)

[!]Restore Default Setting

Restores all setting values that can be set using the menu to the default state. (Page 27)

[Q]Return to Main Menu

Return to the main SETUP MENU. (Page 27)

Note

When “DHCP Client” is set to “OFF” on the projector:

IP address : 192.168.150.2

Subnet mask : 255.255.255.0

Default gateway : 0.0.0.0

-20