5-6 Single Phase Breaker for the receptacle circuit only
Caution : Electric Shock Injuries
z Be sure to disconnect all the loads to the generator when turning the breakers
ON again, after the 1-Phase Breaker has activated.
Disconnect all the loads.
Turn the breaker to ON.
<Caution>
z Do not exceed the maximum output. Refer to 9-2 Output Limitation.
z The 1-P breaker protects the receptacle circuit only.
5-7 The Slow-Down Feature
The slow-down feature is to set the engine speed low automatically (in about 8
seconds) for the purpose of reducing noise and fuel consumption, whenever no
welding operation or electric supply is performed.
In the case of using the SLOW-DOWN feature, turn the slow-down switch to ON. By
the condition, the engine automatically moves to high speed, whenever welding
operation or electric supply starts.
Caution : Damage to the equipment or other properties
z Turn always the slow-down switch to OFF, when the load is incorporated with
any magnet switch.
<Caution>
z When the load of less than 0.5A is connected to use, the Slow-Down feature
does not function sometimes. Therefore, turn the switch to OFF.
z When welding operation or electric supply performs alternately or intermittently,
turn the switch to OFF.
z When the output selector switch is positioned to Eco, the engine does not turn
to high speed.
- 13 -