SPECIFICATIONS

Cartridge Type

Externally Biased Condenser

 

 

Frequency Response

20 to 20,000 Hz (see Figure 4)

 

 

Directional Polar Pattern

Cardioid (see Figure 5)

 

 

Output Impedance

EIA Rated at 150 (140 actual)

 

 

Attenuation Switch

0 or 15 dB attenuation

 

 

Low Frequency response switch

flat; –6 db/octave below 115 Hz;

 

–18 dB/octave below 80 Hz

 

 

Phantom Power

48 Vdc ±4 Vdc (IEC–268–15/DIN 45 596), positive

 

pins 2 and 3

 

 

Current Drain

5.4 mA typical at 48 Vdc

 

 

Common Mode Rejection

50 dB, 20 Hz to 20 kHz

 

 

Polarity

Positive pressure on diaphragm produces positive

 

voltage on output pin 2 relative to pin 3

 

 

Dimensions and Weight

53.0 mm (2.08 in.) maximum body diameter,

 

156.2 mm (6.15 in.) long; 642 grams (22.6 oz.)

 

(see Figure 6)

 

 

Sensitivity (typical, at 1000 Hz;

–37 dBV/Pa

1Pa = 94 dB SPL)

 

 

 

Self–noise (typical, equivalent SPL;

14 dB

A–weighted, IEC 651)

 

 

 

Maximum SPL at 1000 Hz

 

2500 load (Attenuator on)

137 (152) dB

1000 load (Attenuator on)

132 (147) dB

 

 

Output Clipping Level*

 

2500 load

7 dBV

1000 load

1 dBV

 

 

Dynamic Range

 

2500 load

123 dB

1000 load

118 dB

 

 

Signal to Noise ratio**

80 dB

 

 

*20 Hz to 20 kHz; THD < 1%. THD of the microphone preamplifier when applied input signal is equivalent to the cartridge output at specified SPL. **S/N ratio is difference between 94 dB SPL and equivalent SPL of self-noise A-weighted.