Shure manual Microflex MX391 Series Boundary Microphones, Features, Model Variations

Models: MX391

1 12
Download 12 pages 21.89 Kb
Page 1
Image 1

Model MX391 Boundary Microphone User Guide

MICROFLEX MX391 SERIES

BOUNDARY MICROPHONES

Shure MicroflexMX391 Series microphones are small, surface- mounted electret condenser microphones designed for mounting on conference tables, stage floors, and lecterns. Their high sensitivity and wide frequency range make them especially suitable for picking up speech and vocals in sound reinforcement and recording applications.

FEATURES

Flat frequency response across the vocal range for uncolored sound

Interchangeable cardioid, supercardioid, and omnidirectional cartridges that provide optimal choice for each application

Sleek, low-profile design for unobtrusive appearance

New RF filtering

MODEL VARIATIONS

MX391 and MX391W (white) models have an attached 4 meter (12 ft) cable terminated with a 4-pin mini connector and a separate preamplifier, as pictured above in black.

Microflexboundary microphones come with one of three inter- changeable cartridges, as indicated by the model number (found on the bottom of the microphone base).

MX391/C series. Cardioid pickup pattern for general sound reinforce- ment applications. Pickup angle (-3 dB) = 130°.

MX391/S series. Supercardioid pickup pattern for sound reinforce- ment applications requiring narrow or more distant coverage. Pickup angle (-3 dB) = 115°.

MX391/O series. Omnidirectional pickup pattern for recording or re- mote monitoring applications. Pickup angle = 360°.

PERMANENT INSTALLATION

1.Remove the grille from the microphone base by loosening the sin- gle screw on top of the grille, (Figure 1).

WARNING: Do not attempt to detach the cable from the microphone interface.

2.Re-route the cable through the bottom exit hole and pull snug.

3.Use the supplied template (Figure 3) to drill screw holes and a bottom exit hole in the mounting surface.

4.Thread the 4-pin mini connector and cable through the hole of the table.

5.Set the grille back into place and thread the screw through the perforated metal grille and into the microphone interface and tighten.

REPAINTING THE MX391 SERIES

Before applying paint to the MX391 series, remove the grille from the base, remove the foam from the inside of the grill, and mask the microphone cartridge and interface. Also mask the cable where necessary.

Screw Hole

Microphone Interface

Slit

Screw Hole

RE-ROUTING THE CABLE

FIGURE 1

ADJUSTING PREAMP GAIN: MX391 AND MX391W ONLY (FIGURE 4)

MX391 and MX391W microphones include an adjustable gain pream- plifier, allowing the user to specify a 12 dB or 0 dB gain setting. The preamp ships at de 12 dB setting. To reduce the signal gain at the MX391B and MX391W preamplifier by 12dB, replace the gain resis- tors to the 0dB setting, (Table 4A).

RF FILTERING

MX391 Series must be used with RK100PK preamplifier in order to op- timize RF immunity.

Note: Cable shield is NOT connected to pin 1 in the TA4F mini- connector. If you are connecting this microphone to a plastic transmitter, please modify the cable to connect the shield to pin 1. Contact Shure Applications Engineering for assistance.

©2007, Shure Incorporated

 

Printed in U.S.A.

27E3027 (Rev. 2)

 

 