SERVICE INSTRUCTIONS (Cont’d)

PROCEDURE:

First, the meter (7) must be mechanically set to zero. Turn the Power switch (11) OFF and wait one minute. The meter pointer should rest over the mark at the left-hand end of the scale, left of the -20 VU and 0 dB Compression line. Using a small blade screwdriver, rotate the black plastic screw below the meter face to set the pointer, if necessary. The electrical calibrations may now be per- formed as outlined below.

Unless otherwise specified, set all Lo-cut Filter switches

(2)to IN, the Meter switch (8) to DB COMP., the Power (11), Gated Memory (21), and Comp. (22) switches to ON, the Input (14) and Output (17) switches to LINE, and the VU Range switch (4) to +4. Set Output (3) and Input (1) con- trols to 0, except for Input 1 (1A), adjusted as above. Set Response Rate control (6) to 3. Measure all voltages with respect to chassis ground.

GATED MEMORY CALIBRATION:

The Gated Memory calibration should be checked and adjusted before proceeding to the compression system calibration.

Connect meter probe to P.C. Board 3, terminal A, leaving existing gray wire connected, to measure E3A. Adjust input such that E3A is -43.5 dBV (6.6 mV). Red portion of Gated Memory indicator (5) should be exposed.

Adjust input such that E3A is -41.5 dBV (8.4 mV). Red portion of Gated Memory indicator (5) should be covered by white vane.

If steps 2 and 3 are not correct, adjust input such that E3A is -42.5 dBV (7.5 mV) and rotate R318 fully counterclockwise. Gated Memory indicator (5) will be white. Slowly rotate R318 clockwise just until red portion of Gated Memory indicator is exposed. Re- check steps 2 and 3.

COMPRESSION SYSTEM CALIBRATION:

Because of the interdependence of trimmer settings, the following procedure must be followed in the order listed. The Gated Memory must first be properly calibrated as outlined above.

The voltage at terminal L, P.C. Board 4, referred to as E4L, must also be measured. This terminal is a test point with no wire connected to it, and access may most easily be obtained by setting the chassis on its right or left end and inserting the meter probe from the chassis bottom through the rectangular hole near transformers T4 and T5. The temporary wiring change in step 2 may also most easily be done from the bottom of the unit.

Average Level Adjustment (R212).

Set input such that E3A is -30 dBV (31.6 mV). Voltage E4L must be -40 ± 0.2 dBV (10± 0.2 mV). If neces- sary, adjust R212 for the proper E4L reading, but allow 15 seconds of settling time after moving R212 setting to read E4L. If this setting is changed, all subsequent calibration steps must be checked.

Peak Level Adjustment (R211).

Move blue wire from terminal C of P.C. Board 2 to terminal D. Set input such that E3A is -20 dBV (100 mV). Voltage E4L must be -27.5 ± 0.3 dbV (44 ± 3 mV). If necessary, adjust R211 for proper E4L reading. Return blue wire from terminal D of P.C. Board 2 to terminal C.

DB Compression Meter Calibration Check.

A. Set input such that E3A is -40 dBV (10 mV).

Meter pointer should lie over 0 on the DB Com- pression scale.

B.Set input such that E3A is -20 dBV (100 mV). Meter pointer should lie in region occupied by 20 on the DB Compression scale. If either of these

checks is not correct, proceed to step 4.

C. Set input such that E3A is 0 dBV (1.0 V). Meter pointer should lie in region occupied by 40 on the DB Compression scale. If checks A and B are correct, but if this check is not, proceed to step 5.

4.DB Compression Meter Calibration, 0 and 20 Points (R213, R214).

The settings of R213 and R214 interact to calibrate the meter to read 0 when E3A is -40 dBV (10 mV) and to read 20 when E3A is -20 dBV (100 mV).

A.Rotate R215 fully clockwise.

B.Set input such that E3A is -40 dBV (10 mV). Ro- tate R213 for a meter reading of 0.

C.Set input such that E3A is -20 dBV (100 mV). If meter reading is less than 20, rotate R214 slightly clockwise. If meter reading is more than 20, rotate R214 slightly counterclockwise. The effect upon the meter reading at this point is unimportant.

D.Set input such that E3A is -40 dBV (10 mV) and again rotate R213 for a meter reading of 0.

E.Again set input such that E3A is -20 dBV (100 mV) and observe meter for a reading of 20.

F.Repeat steps B through E until meter reads 0 when E3A is -40 dBV (10 mV) and 20 when E3A is -20 dBV (100 mV).

G.Proceed to step 5.

5.DB Compression Meter Calibration, 40 Point (R215). Set input such that E3A is 0 dBV (1.0 V). Rotate R215 until meter reads 40 on the DB Compression scale.

VU METER CALIBRATION:

Proper VU meter calibration is determined by a VU CAL trimmer potentiometer (R529) on P.C. Board 5. The check outlined in step 1 may be performed if P.C. Board 5 has not been replaced, but the procedure of step 2 must be followed if it has been changed.

First, connect a 600-ohm ± 5%, ½ watt resistor (two 1200-ohm, 5%, ¼ watt resistors in parallel may be used) between terminals 3 and 2 of the Line Output connector (20).

1.Calibration check.

A.Set input so that meter reads approximately 20 on the DB Compression scale, with the Meter switch

(8)set to DB COMP.

B.Set the Meter switch (8) to VU and rotate the Out- put control (3) until the meter reads 0 on the VU scale.

C.The voltage measured across the 600 ohm resistor should be 1.8 ± 0.3 dBV (1.23 ± 0.04 V). This is 4.0 ± 0.3 dBm.

2.Calibration procedure.

If meter Ml has been replaced, first check calibration in step 1. If check fails, follow procedure below.

A. Set input such that meter reads approximately 20 on the DB Compression scale, with the Meter switch (8) set to DB COMP.

B. Set the Output control (3) such that the voltage measured across the 600-ohm resistor connected to the Output terminals (20) is 1.8 dBV (1.23 V or 4.0 dBm).

27

Page 27
Image 27
Shure SE30-2 service manual Procedure, Gated Memory Calibration, Compression System Calibration, VU Meter Calibration

SE30, SE30-2 specifications

The Shure SE30-2 and SE30 in-ear monitors are premier audio devices designed for both audiophiles and professionals alike. Renowned for their exceptional sound quality and comfort, these models are essential for anyone serious about their audio experience.

One of the key features of the Shure SE30-2 and SE30 is their detailed sound reproduction. With a frequency response that spans from low bass to crisp highs, these monitors are engineered to deliver a balanced audio experience. The dual-driver configuration in the SE30-2 ensures that low, mid, and high frequencies are rendered with precision, allowing users to appreciate the nuances in their favorite tracks or during live performances.

Comfort is paramount in the design of the SE30 series. These in-ear monitors come with an ergonomic design and a variety of ear tip options, including foam and silicone tips, which help achieve a secure fit. This not only enhances comfort during extended use but also aids in passive noise isolation, allowing users to focus on their music without external distractions.

Shure has integrated innovative technologies into the SE30-2 and SE30 models, including a detachable cable system. This feature allows for easy replacement of worn cables and is particularly useful during live performances, where durability is crucial. The cables are also robust, with reinforced connectors that enhance longevity.

Moreover, the SE30 series is designed with versatility in mind. Whether you are using them in a studio setting, during live performances, or for casual listening, these monitors adapt to deliver optimal performance. The lightweight construction ensures that they are portable and suitable for on-the-go use, making them perfect companions for traveling musicians and audiophiles alike.

In terms of aesthetics, the Shure SE30-2 and SE30 sport a sleek, professional look, available in several color options. This not only appeals to the stylish user but also complements their refinement in sound.

In summary, the Shure SE30-2 and SE30 in-ear monitors present a compelling choice for those who seek high-fidelity audio in a comfortable and durable form factor. With attention to sound quality, comfort, user-friendly designs, and robust construction, these monitors stand out in a market filled with various audio options. Whether for professional use or personal enjoyment, the Shure SE30 series is sure to elevate any listening experience.