New Functions in Version V4.02

New Functions: Forcing with S7-300 Modules

The following table provides an overview of the functions and summarizes the differences between forcing and modifying.

Feature / Function

Force

Modify

 

 

 

 

 

 

 

with S7-400

with S7-300

 

 

 

 

 

 

Bit memory (M)

 

yes

no

yes

 

 

 

 

Timers and counters (T, C)

no

no

yes

 

 

 

 

Data blocks (DB)

no

no

yes

 

 

 

 

Peripheral inputs (PIB, PIW, PID)

yes

no

no

 

 

 

 

Peripheral outputs (PQB, PQW, PQD)

yes

yes *

yes

 

 

 

 

Inputs and outputs (I, Q)

yes

yes *

yes

 

 

 

 

Defining triggers

always trigger

always trigger

yes

 

 

immediately

immediately

(once or every

 

 

 

 

 

 

 

 

cycle)

 

 

 

 

Function only affects variable in visible

affects all

affects all

yes

area of active window.

force values

force values

 

 

 

 

 

User program can overwrite the modify/

no

yes *

yes

force values.

 

 

 

 

 

 

 

 

Replacing the force value effective without

yes

yes

no

interruption.

 

 

 

 

 

 

 

 

The variables retain their values when

yes

yes

no

application is exited.

 

 

 

 

 

 

 

Variables retain their values after the

yes

yes

no

connection to the CPU is broken.

 

 

 

 

 

 

 

Variables retain their values after power

yes

yes

no

off, provided CPU has battery backup.

 

 

 

 

 

 

 

Address error permitted:

no

no

yes

e.g.:

IW1 modify/force value: 1

 

 

the last

 

IW1 modify/force value: 0

 

 

becomes

 

 

 

effective

 

 

 

 

 

 

 

 

 

*The inputs (process-image input table) occupied by force values can be overwritten with: - write instructions (for example, T IB x; = I x.y; copying with SFCs)

- read instructions (for example, L PIW x)

- write programming device/operator panel functions

The outputs occupied by force values can be overwritten with:

-write instructions (for example, T PQB x)

-write programming device/operator panel functions

Supplement to the STEP 7 User Manual V4.0

17

C79000-Z7076-C552-01

Page 17
Image 17