Technical Data
Maximum Capacity USGPH (LPH) 60 Hz | 0.06 (0.24) | 0.16 (0.6) |
| 0.29 (1.08) | 0.44 (1.68) |
|
|
|
|
| |
LPH @ 50 Hz | 0.2 | 0.5 |
| 0.9 | 1.4 |
|
| ||||
|
|
|
|
| |
Max. Back Pressure |
| 120 PSI, 60 Hz / 10 Bar, 50 Hz |
| ||
|
|
|
|
| |
Piston Diameter (mm) | 3 | 4.76 |
| 6.34 | 8 |
|
|
|
|
|
|
Stroke Frequency Max. (SPM) @ 60/50 Hz |
|
| 144 / 122 |
| |
|
|
|
|
| |
Capacity / Stroke Max. (cm3) | 0.027 | 0.068 |
| 0.12 | 0.19 |
|
|
|
|
| |
Accuracy | ± 2 % over 10:1 range (minimum of 20 % stroke length) | ||||
|
|
|
| ||
Max. Suction Lift at 100%* |
| 6 Ft (2 Meters) |
| ||
|
|
|
| ||
Max. Back Pressure of Return |
| 4.5 PSI / 0.3 Bar |
| ||
|
|
|
| ||
Suction and Return |
| 2m Duo Hose 6mm ID Supplied |
| ||
|
|
|
| ||
Metering Discharge |
| 1/4" OD x 0.040" Wall Thickness |
| ||
|
|
|
|
|
|
| 2mm x 4mm |
|
| 4mm x 6mm |
|
|
|
|
| ||
Power Supply |
| 115 V, 60 Hz (230 V, 50 Hz) |
| ||
|
| (Power Cord and Plug Supplied) |
| ||
|
|
|
| ||
Current (mA) 115/230 VAC |
| 172 @ 60 Hz / 81 @ 50 Hz |
| ||
|
|
|
|
| |
Max. Power Input (W) 115/230 VAC |
|
| 18.7 |
| |
|
|
|
|
| |
Enclosure |
|
| IP 65 |
| |
|
|
|
| ||
Max. Ambient Temp. |
| 104°F (40°C) |
| ||
|
|
|
|
| |
Insulation Class |
|
| B |
| |
|
| ||||
Alarm Output | Dry contact 24 V, 3 Amps AC/DC or 240 V, 3 Amps AC/DC | ||||
Low Level and Tank Empty Contact |
|
|
|
|
|
|
| ||||
mA Input | |||||
|
| Max. Impedance 50 Ohms |
| ||
|
|
|
| ||
Pulse Input |
| Dry contact, Min. 15 msec pulse width |
| ||
| E30 Max. Frequency - 144 Pulse/min., E60 & E60 Plus - 50 Hz | ||||
|
| ||||
Stroke Signal Output | 1 Pulse Per Stroke, Dry Contact Rated 24 V DC, 300 mA | ||||
|
|
|
| ||
Weight |
| 6 lbs / 2.4 Kgs |
| ||
|
|
|
|
|
|
Materials of Construction
Pump Head: PVDF
Metering Piston/Cylinder: Ceramic
Diaphragm:
Valves: PVDF
Valve Balls: Ceramic
Valve Springs: Hastelloy
Housing/Finish: Thermoplastic Polyester
* Suction lifts with clean, wetted valves
Suction Lance with tank level switches is recommended for all capacities. All data refers to water at 68ºF as per the instruction manual.
www.usfilter.com
The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Chem- Ad and PM Kits are registered trademarks of Siemens.
Dimensions (See Literature)
CN 441.600 - Unit Dimensions
CN 441.601 - E11/E30 Control Panel
CN 441.630 -
CN 441.650 - OGM Dimensions
Siemens Water Technologies 1901 West Garden Road Vineland, NJ 08360 www.usfilter.com wtus.water@siemens.com
TI
Subject to change without prior notice