UARTIIR/UARTICR R/W Addr.: 0x4000_231C Default: 0x00
Description UART interrupt identification register (read)
UART interrupt clear register (write)
Bit No. Name Description
0 MIS (Read) Modem Interrupt Status This bit is set if UARTMSINTR is active.
1 RIS (Read) Receive Interrupt Status This bit is set if UARTRXINTR is active.
2 TIS (Read) Transmit Interrupt Status This bit is set if UARTTXINTR is active.
3 RTIS (Read) Receive Timeout Interrupt Status This bit is set if UARTRTINTR is active.
7 – 4 ----- (Read) Reserved
Value is undefined
7 – 0 ----- (Write) Writing to this register deletes the MIS bit irrespective of the value written.
UARTILPR R/W Addr.: 0x4000_2320 Default: 0x00
Description UART IrDA low power counter registers
(not supported in the ERTEC 200)
Bit No. Name Description
7 – 0 ILPDVSR 8-bit low power divisor value
NOTE: The low power divisor is calculated according to the following formula:
FUARTCLK
ILPDVSR = ---------------------- - 1 FIrLPBAUD16 is nominally 1.8432 MHz
FIrLPBAUD16
Zero is not a valid divisor.
Copyright © Siemens AG 2007. All rights reserved. 53 ERTEC 200 Manual
Technical data subject to change Version 1.1.0