This section contains troubleshooting information. This information covers only the most common problems that you may encounter. If you cannot solve the problem with the information given here, contact your local Siemens Airfield Solutions representative for help.

 

Problem

Possible Cause

Corrective Action

1.

Lamp will not

Defective lamp

Replace lamp and film disc cutout (if used).

 

energize

 

Refer to Replacing Lamp in the Maintenance

 

 

 

section.

 

 

Loose or broken contacts

Tighten or replace.

 

 

Moisture inside assembly causing

Open up light assembly. Clean, dry, and

 

 

current leakage

inspect light assembly. Replace O-ring.

 

 

Defective isolation transformer

Check transformer output current with

 

 

 

meter.

 

 

 

 

2.

Lamp not turning on

Continuity incorrect

Check lamp filament and wiring for

 

at normal level

 

continuity.

3.

Lamp output

Broken or damaged prism

Replace outer cover assembly.

 

distorted

 

 

4.

Improper color

Filter broken

Replace filter bracket assembly.

 

 

Filter bracket broken

Replace filter bracket assembly.

 

 

 