| Problem | Possible Cause | Corrective Action |
1. | Lamp will not | Defective lamp | Replace lamp and film disc cutout (if used). |
| energize |
| Refer to Replacing Lamp in the Maintenance |
|
|
| section. |
|
| Loose or broken contacts | Tighten or replace. |
|
| Moisture inside assembly causing | Open up light assembly. Clean, dry, and |
|
| current leakage | inspect light assembly. Replace |
|
| Defective isolation transformer | Check transformer output current with |
|
|
| meter. |
|
|
|
|
2. | Lamp not turning on | Continuity incorrect | Check lamp filament and wiring for |
| at normal level |
| continuity. |
3. | Lamp output | Broken or damaged prism | Replace outer cover assembly. |
| distorted |
|
|
4. | Improper color | Filter broken | Replace filter bracket assembly. |
|
| Filter bracket broken | Replace filter bracket assembly. |
|
|
| Continued on next page |
© 2001 Siemens Airfield Solutions, Incorporated | 96A0149E | Page 23 |