Standby Generator Sets

Maintenance

‹CHANGING ENGINE OIL

Refer to maintenance performed by service facilities for engine oil and filter change frequencies.

Drain the oil while the engine is still warm from run- ning. This means warm up the engine, shut it down and drain immediately as follows:

1.Remove OIL DRAIN HOSE from its retaining clip.

2.Loosen and remove OIL DRAIN HOSE CAP. Drain oil completely into suitable container.

3.When all oil has drained, install and tighten OIL DRAIN HOSE CAP, and re-install into its retaining clip.

4.Turn OIL FILTER (Figure 10.2) counterclockwise and remove. Properly dispose of old filter.

Figure 10.3 – Engine Air Cleaner

Air Cleaner

Figure 10.2 – Oil Filter

Oil

Filter

5.Apply light coating of new engine oil to seal of new oil filter.-Install FILTER and tighten by hand only.

DO NOT OVER TIGHTEN.

6.Remove OIL FILL CAP. Add recommended oil (see

SPECIFICATIONS). DO NOT FILL ABOVE THE DIPSTICK “FULL” MARK. Crankcase oil capacity is 4.0 U.S. quarts (3.8 liters).

After refilling the crankcase with oil, always check oil level on dipstick. NEVER OPERATE ENGINE WITH OIL BELOW THE DIPSTICK “ADD” MARK.

7. Start engine and check for oil leaks.

(Doors Removed for Clarity)

‹SPARK PLUGS

Reset the spark plug gap or replace the spark plugs as necessary (Figure 10.4).

1.Clean the area around the base of the spark plugs to keep dirt and debris out of the engine. Clean by scraping or washing using a wire brush and commercial solvent. Do not blast the spark plugs to clean.

2.Remove the spark plugs and check the condition. Replace the spark plugs if worn or if reuse is questionable. See the “Service Schedule” section for recommended inspection.

3.Check the spark plug gap using a wire feeler gauge. Adjust the gap to 1.07-1.17 mm (0.042- 0.046 inch) by carefully bending the ground elec- trode (Figure 10.4).

Figure 10.4 – Setting the Spark Plug Gap

SET PLUG GAP AT 1.07 - 1.17 mm

(0.042 - 0.046 inch)

‹ CHANGING THE ENGINE AIR CLEANER

 

‹ COOLANT CHANGE

To replace the engine air cleaner, remove the air cleaner cover and replace the air filter making sure it is positioned properly before reattaching the cover (Figure 10.3).

See the “Service Schedule,” for air cleaner mainte- nance.

Every year, have a service facility drain, flush and refill the cooling system. See “Specifications” for cool- ing system recommendations.

10-3

05/06 A .Rev Maint012

Page 18
Image 18
Siemens SG035 owner manual ‹ Changing Engine OIL, ‹ Spark Plugs, ‹ Changing the Engine AIR Cleaner ‹ Coolant Change

SG035 specifications

The Siemens SG035 is a versatile and innovative solution designed for the modern industrial landscape. As a significant model within Siemens’ range of power generation equipment, the SG035 delivers reliable performance, advanced technology, and a commitment to sustainability. This article explores the main features, technologies, and characteristics that set the Siemens SG035 apart from its competitors.

One of the primary features of the Siemens SG035 is its impressive power output. It is engineered to provide a substantial amount of energy, making it ideal for a wide range of applications, from industrial to commercial settings. The unit is equipped with a state-of-the-art generator that ensures maximum efficiency and minimal energy losses.

The SG035 incorporates cutting-edge technology that enhances its operational capabilities. For instance, it utilizes advanced control systems that allow for real-time monitoring and adjustments, ensuring optimal performance under varying load conditions. These control systems are designed with user-friendly interfaces, making it easier for operators to manage the equipment.

In terms of design, the Siemens SG035 boasts a compact and modular architecture. This allows for easy integration into existing energy systems, saving valuable space on facilities. Furthermore, its modular design facilitates rapid installation and maintenance, reducing downtime and operational costs.

Another significant characteristic of the SG035 is its focus on sustainability. It has been engineered to meet stringent environmental standards, including low emissions and high energy efficiency. The use of environmentally friendly materials in its construction further underscores Siemens’ commitment to sustainable practices.

The Siemens SG035 also prioritizes safety and reliability. It is built with robust components designed to withstand harsh operating conditions. Additionally, extensive safety features are integrated into the system to protect both the equipment and the personnel operating it.

Overall, the Siemens SG035 stands out in the field of power generation equipment due to its powerful performance, advanced technologies, compact design, and commitment to environmental sustainability. As industries continue to evolve and require more efficient energy solutions, the Siemens SG035 positions itself as a reliable choice for meeting contemporary energy demands while prioritizing safety, efficiency, and the environment. This makes it a significant player in the move towards a more sustainable future in energy production.