Siemens SG035 owner manual  Warning 

Models: SG035

1 64
Download 64 pages 3.28 Kb
Page 3
Image 3

Standby Generator Sets

Important Safety Instructions

SAVE THESE INSTRUCTIONS – The manufacturer suggests that these rules for safe operation be copied and posted in potential hazard areas. Safety should be stressed to all operators, potential operators, and service and repair technicians for this equipment.

WARNING:

The engine exhaust from this product contains chemicals known to the state

of California to cause cancer, birth defects or other reproductive harm.

WARNING:

This product contains or emits chemicals known to the state of California to cause cancer, birth defects or other reproductive harm.

Study these SAFETY RULES carefully before install- ing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely, efficiently and reli- ably only if it is properly installed, operated and maintained. Many accidents are caused by failing to follow simple and fundamental rules or precautions.

The manufacturer cannot anticipate every possible circumstance that might involve a hazard. The warn- ings in this manual, and on tags and decals affixed to the unit are, therefore, not all inclusive. If a pro- cedure, work method or operating technique is used that the manufacturer does not specifically recom- mend, ensure that it is safe for others. Also make sure the procedure, work method or operating tech- nique utilized does not render the generator unsafe.

DANGER

Despite the safe design of this generator, operating this equipment imprudently, neglect- ing its maintenance or being careless can cause possible injury or death. Permit only responsible and capable persons to install, operate or main- tain this equipment.

Potentially lethal voltages are generated by these machines. Ensure all steps are taken to render the machine safe before attempting to work on the generator.

Parts of the generator are rotating and/or hot during operation. Exercise care near running generators.

1-1

GENERAL HAZARDS

For safety reasons, the manufacturer recommends that this equipment be installed, serviced and repaired by an Authorized Service Dealer or other competent, qualified electrician or installation tech- nician who is familiar with applicable codes, stan- dards and regulations. The operator also must comply with all such codes, standards and regula- tions.

Installation, operation, servicing and repair of this (and related) equipment must always comply with applicable codes, standards, laws and regulations. Adhere strictly to local, state and national electri- cal and building codes. Comply with regulations the Occupational Safety and Health Administration (OSHA) has established. Also, ensure that the generator is installed, operated and serviced in accordance with the manufacturer’s instructions and recommendations. Following installation, do nothing that might render the unit unsafe or in noncompliance with the aforementioned codes, standards, laws and regulations.

The engine exhaust fumes contain carbon monox- ide gas, which can be DEADLY. This dangerous gas, if breathed in sufficient concentrations, can cause unconsciousness or even death. For that reason, adequate ventilation must be provided. Exhaust gases must be piped safely away from any building or enclosure that houses the generator to an area where people, animals, etc., will not be harmed. This exhaust system must be installed properly, in strict compliance with applicable codes and stan- dards.

Keep hands, feet, clothing, etc., away from drive belts, fans, and other moving or hot parts. Never remove any drive belt or fan guard while the unit is operating.

Adequate, unobstructed flow of cooling and venti- lating air is critical in any room or building hous- ing the generator to prevent buildup of explosive gases and to ensure correct generator operation. Do not alter the installation or permit even partial blockage of ventilation provisions, as this can seri- ously affect safe operation of the generator.

Keep the area around the generator clean and uncluttered. Remove any materials that could become hazardous.

When working on this equipment, remain alert at all times. Never work on the equipment when physically or mentally fatigued.

Inspect the generator regularly, and promptly repair or replace all worn, damaged or defective parts using only factory-approved parts.

08/05

0 .Rev 001 Safety

Page 3
Image 3
Siemens SG035 owner manual  Warning 

SG035 specifications

The Siemens SG035 is a versatile and innovative solution designed for the modern industrial landscape. As a significant model within Siemens’ range of power generation equipment, the SG035 delivers reliable performance, advanced technology, and a commitment to sustainability. This article explores the main features, technologies, and characteristics that set the Siemens SG035 apart from its competitors.

One of the primary features of the Siemens SG035 is its impressive power output. It is engineered to provide a substantial amount of energy, making it ideal for a wide range of applications, from industrial to commercial settings. The unit is equipped with a state-of-the-art generator that ensures maximum efficiency and minimal energy losses.

The SG035 incorporates cutting-edge technology that enhances its operational capabilities. For instance, it utilizes advanced control systems that allow for real-time monitoring and adjustments, ensuring optimal performance under varying load conditions. These control systems are designed with user-friendly interfaces, making it easier for operators to manage the equipment.

In terms of design, the Siemens SG035 boasts a compact and modular architecture. This allows for easy integration into existing energy systems, saving valuable space on facilities. Furthermore, its modular design facilitates rapid installation and maintenance, reducing downtime and operational costs.

Another significant characteristic of the SG035 is its focus on sustainability. It has been engineered to meet stringent environmental standards, including low emissions and high energy efficiency. The use of environmentally friendly materials in its construction further underscores Siemens’ commitment to sustainable practices.

The Siemens SG035 also prioritizes safety and reliability. It is built with robust components designed to withstand harsh operating conditions. Additionally, extensive safety features are integrated into the system to protect both the equipment and the personnel operating it.

Overall, the Siemens SG035 stands out in the field of power generation equipment due to its powerful performance, advanced technologies, compact design, and commitment to environmental sustainability. As industries continue to evolve and require more efficient energy solutions, the Siemens SG035 positions itself as a reliable choice for meeting contemporary energy demands while prioritizing safety, efficiency, and the environment. This makes it a significant player in the move towards a more sustainable future in energy production.