TC12 Installation, Commissioning & Maintenance Handbook
Figure 35 - LMU Input Connector
60 Way Connector to LMU Inputs
PLB
PIN SIG NAME BERG
PIN PLB
PIN SIG NAME BERG
PIN
1 LMU input 1 + 3 * 25 LMU input 13 + 27
2 LMU input 1 - 4 26 LMU input 13 - 28
3 LMU input 2 + 5 27 LMU input 14 + 29
4 LMU input 2 - 6 28 LMU input 14 - 30
5 LMU input 3 + 7 29 LMU input 15 + 31
6 LMU input 3 - 8 30 LMU input 15 - 32
7 LMU input 4 + 9 31 LMU input 16 + 33
8 LMU input 4 - 10 32 LMU input 16 - 34
9 LMU input 5 + 11 33 LMU input 17 + 35
10 LMU input 5 - 12 34 LMU input 17 - 36
11 LMU input 6 + 13 35 LMU input 18 + 37
12 LMU input 6 - 14 36 LMU input 18 - 38
13 LMU input 7 + 15 37 LMU input 19 + 39
14 LMU input 7 - 16 38 LMU input 19 - 40
15 LMU input 8 + 17 39 LMU input 20 + 41
16 LMU input 8 - 18 40 LMU input 20 - 42
17 LMU input 9 + 19 41 LMU input 21 + 43
18 LMU input 9 - 20 42 LMU input 21 - 44
19 LMU input 10 + 21 43 LMU input 22 + 45
20 LMU input 10 - 22 44 LMU input 22 - 46
21 LMU input 11 + 23 45 LMU input 23 + 47
22 LMU input 11 - 24 46 LMU input 23 - 48
23 LMU input 12 + 25 47 LMU input 24 + 49
24 LMU input 12 - 26 48 LMU input 24 - 50
49 to
60 No Connection
* Important note: The Berg connector is a 64 position header to allow correct mating
with the 60 Way IDC connector. There are four unused positions on the Berg which
have no associated mate on the IDC connector located on the PCB. Consequently,
positions 1, 2, 63 and 64 on the Berg header have no connection to them. This
corresponds to the top pair of holes and the bottom pair of holes.
666/HE/43100/000 Page 173 Issue 9