Features

Temperature / system monitoring

Fan monitoring

The CPU, power supply unit and system fans are monitored. Fans that are no longer available, blocked or sticky fans are detected.

Fan control

The fans are regulated according to temperature.

Sensor monitoring

The removal of, or a fault in, a temperature sensor is detected. Should this happen all fans monitored by this sensor run at maximum speed, to achieve the greatest possible protection of the hardware.

Voltage monitoring

When voltage exceeds warning level high or falls below warning level low an alert will be generated.

Cover monitoring

Unauthorized opening of the cover is detected, even when the system is switched off. However, this will only be indicated when the system is switched on again.

System Event Log (SEL)

All monitored events of the system board are signalized via the Global Error LED and recorded in the System Event Log. They could be retrieved in the BIOS Setup or via ServerView.

D2559 (TX150 S6)

Technical Manual

21

Page 21
Image 21