Installation and Maintenance
5.4 Wall Mounting
Figure 5-3 Installation of a SCALANCE X-100 and/or X-200 on a SIMATIC S7-300 Standard Rail
Uninstalling
To remove the Industrial Ethernet switches of the SCALANCE X-100 and X-200 product
lines from the SIMATIC S7-300 standard rail:
1. First disconnect the TP cables and pull out the terminal blocks for the power supply and
the signaling contact.
2. Loosen the screws on the underside of the standard rail and lift the device away from the
standard rail.
5.4 Wall Mounting Wall Mounting
1. For wall mounting, use suitable mounting fittings for the wall
(for example, for a concrete wall, four plugs 6 mm diameter and 30 mm long, 4 screws
3.5 mm diameter and 40 mm long).
2. Connect the electrical wiring to the terminal block.
3. Fit the connectors for the signaling contact to the terminal block.
4. Insert the two terminal blocks into the sockets on the device.
For more exact dimensions, please refer to the section "Dimension Drawings".
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
5-4 Commissioning Manual, 1,