Model 5398-21 Gas Sample Draw Panels

Model 5398-21 Model 5398-21Gas Sample Draw Panels

Gas Sample Draw Panel (5398-21) provides an easy to

 

 

use method of drawing an air sample from a remote, or

 

 

hostile area to a more convenient location for analysis.

 

 

The Sample Draw Panel can use gas sensor modules

 

 

for Combustible or Toxic gases, either the Sentry style

 

 

modules or the Analog (4-20 mA output) modules. It

 

 

can use gas sensor modules for Combustible or Toxic

 

 

gases.

 

 

 

 

The integral sample pump to draw the sample at a high

 

 

flow rate to reduce sample time. The sample is delivered

 

 

to the sensor up-stream from the pump to avoid negative

 

 

pressure conditions. A bypass line exhausts excess

 

 

sample volume to avoid high flow rates across the sensor.

 

 

Each panel is a self-contained system with the pump,

 

 

flow indication, valves to control sample draw and

 

Model 5398-21

calibration gas delivery, and the gas detection sensor

 

 

 

and transmitter (priced separately) all housed in an

The Sample Draw Panels are intended for installation in

enclosure. The flow systems design will deliver the

an area, which is accessible, by the user for periodic

sample to the sensor with minimal pressure affecting

routine inspection and calibration. The panel requires

the sensor as the excess flow and pressure are bled off

120 VAC input and provides local visual as well as

via the bypass flowmeter.

 

remote indication of pump and flow status.

Specifications:

 

 

 

 

Power:

 

110 VAC @ 1 amp

 

Pump:

 

Oil Free, Diaphragm Type

Maximum Sample Draw:

600 feet with 1/4” tubing

 

Flow Rates:

 

0-500 cc/min. Adjustable sample to sensor

Maximum Operating Pressure:

50 PSIG

 

Controls:

 

3-way valve for Run and Calibration

Outputs:

 

Dry contact pump flow failure switch (contacts closed when

 

 

flow is detected, open for alarm)

Filter:

 

Coalescing filter for moisture knock-out for each sample line

Tubing Connections:

 

1/4" Tube Fittings for connection of:

 

 

- sample lines

- sample exhausts

 

 

- calibration gas

- bypass exhaust

Enclosure type:

 

NEMA 4X Fiberglass with window

Dimensions (H x W x D):

16.9 x 15.0 x 8.3 inches (42.9 x 38.1 x 21.1 cm)

Weight:

 

17.6 lbs (8.0 Kg) - without gas sensor module

Sensor/Transmitter:

 

Mounting provisions for all standard Sierra Monitor Corp.

Ordering Information:

 

Sentry and Analog gas sensor modules

 

 

 

 

Model 5398-21

Single Channel Gas Sample Panel

 

Model 5398-21 Dimensions

Sierra Monitor Corporation 1991 Tarob Court Milpitas, CA 95035 USA (408) 262-6611 (800) 727-4377 Fax: (408) 262-9042

Visit our Web site: www.sierramonitor.com

E-Mail: sierra@sierramonitor.com

© 2009 by Sierra Monitor Corporation
Page 1
Image 1
Sierra Monitor Corporation specifications Model 5398-21 Gas Sample Draw Panels, Specifications, Ordering Information