Removing the brush caps: Using a small flat blade screw driver rem ove one brush cap at a tim e. Care should be taken as the brush holder has a spring that forces to the brush onto the arm ature. This
spring may cause the cap to pop out unless held firm ly
(Figure 5).
Removing and dressing the brush: Rem ove the brush from the holder by lifting up
and sliding the brush and spring clear (Figure 5). Once the brush is clear hold the brush base and carefully take a couple of swipes across the brush face with fine sand paper (Figure 6).
Figure 6 | NO TE: W HEN SANDING THE FACE OF THE BRUSH DO NOT | |
REMOVE ANY MATERIAL. W E ARE ONLY SCUFFING THE | ||
| ||
| SURFACE TO ALLOW FOR BETTER BRUSH CONTACT. | |
| Reinstalling the brush: Insert the brush back into the holder. Hold the | |
| term inal tab into the holder. Carefully insert the cap and turn with a | |
| sm all flat bladed screw driver. Use care not to cross thread the cap. | |
| Once the cap is threaded lightly tighten against term inal tab (Figure 7). | |
| Repeat service on lower brush. | |
| Assembly: | |
| Reconnect motor | |
| wires to red and | |
| black term inals. | |
| Check fan blade for | |
| bent blades by | |
| spinning by hand. If | |
| blades are not | |
| aligned carefully | |
Figure 7 | bend back into | |
place. | ||
Carefully reinstall upper rear panel (Figure 8). |
| |
| Figure 8 |
After completing the installation of the rear panel and tightening all the phillips screws. Plug the heater back into AC power and test run by
running fan motor on “Fan” setting for 2 minutes and then running on “Clean” for 30 seconds. Open hopper lid and run unit through a beginning start up by pressing “Low” and allowing fan to ignitor and fan to start up. If all appears to activate reinstall unit.
Additional inform ation is available on line@ www.sierraproductsinc.net/pages/custom er_service
Technical Custom er Service -
5061 Brooks St. Ste B Montclair, CA 91763
www.sierraproductsinc.net
P/N Fan Motor Brush Service 08 10/08