Configuring the MP Modem to Report GPS and I/O Data
Digital I/O setup
The Digital Input/Output window (Tools > Options > MP >
Input/Output > Digital I/O) is used to configure devices on the two
digital I/O and two digital input ports. Each tab corresponds to
a pin:
Digital Tab Connector Pin
I/O 1 Input or output on pin 3
I/O 2 Input or output on pin 11
Input 3 Input on pin 4
Input 4 Input on pin 12
To configure a digital sensor or gauge, select the tab that corre-
sponds to the pin you are using and complete the fields as
follows:
Label: Provide a description of the sensor or gauge, up to
20 characters in length.
Type : Select Input, Output, or Not used. (Output is not
available on tabs 3 and 4.)
Logic low name: Describe the state of the device at logic
level low, up to 20 characters in length. (For example, if a
switch in the off position leads to a logic low, you could
choose to label it Switched Off.)
Logic high name: Describe the state of the device at logic
level high, up to 20 characters in length (such as Switched
On).
Alarm logic level: Assign an action associated with the I/O
port:
· high: A notification is sent, and the event is logged, if the
state changes from a logic low to a logic high.
· low: A notification is sent, and the event is logged, if the
state changes from a logic high to a logic low.
· log only: No notification is sent, but any change in logic
level is logged.
The name and location of the log file is specified in the
Input/Output window (Tools > Options > MP > Input/Output).
By default, the log file is located in the program folder or
user folder and is and called MpIoLog.txt.
Current value: Shows the current value of the port.
Rev 1.3 Aug.07 49