Sigma 1457, 1433-000-E, 1456, 1434-000-E service manual Sequence Of Operation Impinger Advantage

Models: 1434-000-E 1457 1456 1433-000-E

1 28
Download 28 pages 48.2 Kb
Page 2
Image 2

SEQUENCE OF OPERATION

IMPINGER ADVANTAGE

SERIAL NUMBER N28654 AND ABOVE (OVENS WITH PUSH BUTTON CONTROLS)

MODEL 1433-000-E

230VAC

50 HZ.

NAT. GAS

MODEL 1434-000-E

230VAC

50 HZ.

LP GAS

MODEL 1456

 

220/240VAC

50 HZ.

NAT. GAS

MODEL 1457

 

220/240VAC

50 HZ.

LP GAS

 

 

POWER SUPPLY

Electrical power is to be supplied to the oven by a three conductor

 

service.

 

 

 

Brown conductor is hot.

 

 

Blue conductor is neutral.

 

 

Green conductor is ground.

 

CONTROL BOX AUTO

When the temperature in the control box reaches 120°F ± 3°F (48.9°C

COOL DOWN

±

°

 

 

 

1.7 C), the cooling fan thermostat will switch power to the control

 

box cooling fan. The thermostat will interrupt power to the cooling fan

 

when the control box temperature falls to 100°F ± 3°F (37°C ± 1.7°C).

MAIN FAN CIRCUIT

Electrical power is permanently supplied, through the 10 Amp oven

 

fuse, to a normally open contact of the oven power switch. Power is

 

also supplied to the control box cooling fan. Closing the oven power

 

switch supplies line voltage to the main fan motor. Closing the oven

 

power switch also supplies line voltage to the heat circuit and to the

 

primary of the oven control transformer.

BURNER CIRCUIT

Closing the oven power switch supplies line voltage through the main

 

fan air pressure switch, through the normally closed oven cavity hi-limit

 

thermostat. Through the gas pressure proving switch (gas pressure

 

switch removed at S/N N31348) to the ignition control. The combustion

 

motor is now energized, the normally open combustion air switch

 

closes upon sensing air. After a pre-purge period between 30 and 60

 

seconds, the spark generator and the main gas valve are energized.

 

Ignition should now occur

 

TEMPERATURE CONTROL

Closing the oven fan switch supplies line voltage to the primary of the

 

control transformer and through the ignition control, to the oven

 

control. Secondary voltage, 24VAC, is supplied to the oven control.

 

The oven control is set to desired temperature. The thermocouple will

 

provide varying millivolts to the oven control. The oven control supplies

 

line voltage to the temperature regulation valve at intermittent intervals

 

to maintain desired temperature. The display on the oven control will

 

indicate when the temperature regulation valve is energized.

 

NOTE: The display also indicates oven temperature.

CONVEYOR DRIVE

Closing the oven power switch supplies line voltage to the conveyor

 

motor and to the primary of the control transformer. Secondary

 

voltage, 24VAC, is supplied to the oven control. Setting the oven

 

control to the desired time outputs voltage, through a reversing switch,

 

to the conveyor motor.

 

 

NOTE: The conveyor system uses a hall effect sensor and magnet to

 

prove operation of the conveyor motor. If the motor is not running,

 

“BELT JAM” is indicated on the display.

2

Impinger I – Adv Digital – Gas Service Manual – International

Page 2
Image 2
Sigma 1457, 1433-000-E, 1456, 1434-000-E service manual Sequence Of Operation Impinger Advantage