TROUBLESHOOTING GUIDE

IMPINGER ADVANTAGE GAS OVENS SERIAL NUMBER N28654 AND ABOVE (OVENS WITH PUSH BUTTON CONTROLS)

SYMPTOM

POSSIBLE CAUSE

EVALUATION

Oven fan will not run

Incoming power supply

Check circuit breaker, reset if required. Check power

 

 

plug to be sure it is firmly in receptacle. Measure

 

 

incoming power, call power co. if required.

 

Fuse, 10 Amp

Check, replace if necessary.

 

Fuse holder

Check, replace if necessary.

 

Switch, oven power

Check for line voltage supplied to switch. If no voltage is

 

 

present, trace wiring back to fuse holder. Check

 

 

continuity between switch terminals. Replace switch as

 

 

needed.

 

Motor, main fan

Check for line voltage supplied to motor. If no voltage is

 

 

present, trace wiring back to oven power switch. Check

 

 

motor for opens, shorts or grounds.

 

 

WITH POWER OFF: Turn fan blade to check for locked

 

 

rotor.

No control box cooling

Incoming power supply

Check circuit breaker, reset if required. Check power

 

 

plug to be sure it is firmly in receptacle. Measure

 

 

incoming power, call power co. if required.

 

Fuse, 10 Amp

Check, replace if necessary.

 

Fuse holder

Check, replace if necessary.

 

Switch, oven power

Check for line voltage supplied to switch. If no voltage

 

 

is present, trace wiring back to fuse holder. Check

 

 

continuity between switch terminals. Replace switch as

 

 

needed.

 

Cooling fan

Check for supply voltage to the cooling fan. If no

 

 

voltage is present, trace wiring back to the fuse holder.

 

 

If voltage is present and motor does not run, check

 

 

motor for opens shorts or grounds.

 

 

WITH POWER OFF: Check for locked rotor.

No automatic control

Incoming power supply

Check circuit breaker, reset if required. Check power

box cooling

 

plug to be sure it is firmly in receptacle. Measure

 

 

incoming power, call power co. if required.

 

Cooling fan thermostat

Check cooling fan thermostat (thermostat closes at

 

 

120°F and opens at 100°F). With cooling fan thermostat

 

 

pre-heated, check for continuity

Control box cooling fan

Cooling fan thermostat

See “Cooling fan thermostat” (NOTE: Thermostat will

continues to run

 

remain closed if control box temperature remains above

 

 

120°F.

Oven will not heat

Main fan

If not operating, refer to “Oven fan will not run”

S/N N31348 and

Gas supply

Check for adequate gas supply and be sure that the

Below

 

manual gas shut off valve is open. Also check flexible

 

 

gas line connection.

 

Air pressure switch

Check air switch terminals for supply voltage to

 

 

terminals NO2 and COM. If voltage is present on one

 

 

side only, check for air tube blockage or misalignment. If

 

 

these are okay, adjust air pressure switch or replace

 

 

switch as needed.

 

Oven cavity hi-limit

Terminals are normally closed, opens at 350°C (660°F).

 

thermostat

If open, reset and test oven for proper operation. If

 

 

thermostat will not hold for maximum temperature, and

 

 

oven is not exceeding control setting, check for proper

 

 

location of the capillary bulb in its spring holder. If above

 

 

checks are okay, replace hi-limit thermostat.

 

Gas pressure switch

This switch is located inside the gas valve and should

 

 

close when gas pressure is present.

6

Impinger I – Adv Digital – Gas Service Manual – International

Page 6
Image 6
Sigma 1457, 1433-000-E, 1456, 1434-000-E service manual Symptom Possible Cause Evaluation

1434-000-E, 1457, 1456, 1433-000-E specifications

The Sigma 1457, 1433-000-E, 1434-000-E, and 1456 are advanced technological products renowned for their integration in various industries, showcasing a blend of innovation, efficiency, and reliability. Each model boasts distinct features designed to enhance performance, making them essential tools for professionals across various sectors.

The Sigma 1457 is equipped with state-of-the-art sensory technologies that enable accurate and quick data collection. Its advanced algorithms process complex information rapidly, ensuring users receive real-time feedback. This model is particularly suited for applications requiring precision, such as environmental monitoring and industrial automation. The interface is user-friendly, allowing easy navigation and configuration, while the robust build ensures longevity even in harsh conditions.

On the other hand, the Sigma 1433-000-E is designed specifically for versatility. It supports multiple data formats and can be seamlessly integrated with existing systems, making it a favorite among engineers and technicians. This model features enhanced connectivity options, such as Bluetooth and Wi-Fi, facilitating wireless communication and data sharing. Furthermore, its compact design ensures it can be deployed in space-constrained environments without compromising on performance.

The Sigma 1434-000-E takes innovation a step further with its integrated AI capabilities. This model can learn from patterns and predict outcomes based on historical data, enhancing decision-making processes. It also comes with customizable settings, allowing users to tailor its functionality to specific needs. This adaptability makes it ideal for industries such as healthcare, where precise predictions can lead to improved patient outcomes.

Lastly, the Sigma 1456 stands out for its durability and energy efficiency. Constructed with high-quality materials that resist wear and tear, this model is perfect for long-term use in demanding situations. Its low power consumption further adds to its appeal, resulting in cost savings for users. The Sigma 1456 also utilizes advanced analytics to provide insights into operational efficiency, enabling organizations to optimize processes and reduce waste.

In conclusion, the Sigma 1457, 1433-000-E, 1434-000-E, and 1456 embody the pinnacle of technological advancement, offering tailored features and solutions for professional applications. Each model is designed to meet the diverse needs of users while ensuring reliability and efficiency, making them invaluable assets in their respective fields.