Hazardous voltage

Installation / Operation

2

INSTALLATION

1.Locate pump as close as possible to water being pumped. Pump must be less than 10 feet (3m) above water reservoir and less than 25 feet (7.6m) to one side of reservoir.

2.To help priming, pour one tablespoon of cooking oil or mineral oil in inlet port before each use. Do this every time you start the pump.

3.Mount pump solidly on a stable platform.

Risk of electrical shock. Protect motor from rain or washdown; it is enclosed but not waterproof.

4.Make sure washer in inlet fitting is clean and in good condition. If this joint leaks air in, pump will not operate.

5.Install a strainer or the Pud-L-Scoop®to pro- tect the pump from large solids (Pud-L-Scoop®is included with Models M40P-01 and M40P-03 only). When attached to a water suction pump, the Pud-L-Scoop®will pump water down to within 1/8” of the surface it is sitting on. Uses include floors, roofs, pool covers, and boat bilges. The threadless rubber grommet can be connected to a 3/4” pipe or garden hose. The washer end of the rubber grommet inserts into the Pud-L-Scoop®and the tapered end is for the hose connection. Place the Pud-L-Scoop®at the lowest point in the area to be pumped and it is ready for use.

6.Attach inlet and discharge hoses to pump. Use a reinforced inlet hose 1/2" (12.7mm) in diameter or larger. Be sure inlet hose is airtight and that both hoses are free of kinks and restrictions.

7.Make sure hoses are as straight as possible. Coils in the hoses can develop enough fric- tion to prevent pump from operating.

8.When pumping from a well or stream, raise inlet hose a few inches from the bottom to prevent pump sucking sand, silt or pebbles (foreign matter will disable impeller).

9.Plug motor cord into a 3-wire grounded 115 volt 60 Hz. A.C. outlet. If necessary, use a

3-wire, grounded extension cord to connect the pump motor to the grounded outlet. Use a size 16 AWG cord up to 25 feet; do not use a cord more than 25 feet long. Keep the pump, cord, and outlet dry at all times.

Use this pump only on 115 volt circuit. Pump is equipped with an approved 3-conductor cord and 3-prong, grounding-

type plug. To reduce the risk of electric shock, be certain that it is connected to a properly grounded, grounding-type receptacle.

Where a 2-prong wall receptacle is encoun- tered, it must be replaced with a properly grounded 3-prong receptacle installed in accor- dance with the National Electrical Code and local codes and ordinances.

NOTICE: PUMP DEPENDS ON LIQUID BEING PUMPED FOR LUBRICATION. DO NOT RUN PUMP DRY!

10.Pump should prime within 30 seconds. If not, unplug pump and do the following:

a.Disconnect inlet hose at pump. Pour another tablespoon of mineral oil into inlet port.

b.Check washers in inlet hose and make sure inlet line is airtight.

c.Make sure inlet and discharge line are free of kinks and restrictions.

d.Make sure pump is less than 10' (3m) above and 25' (7.6m) to one side of water source.

11.If pump does not prime within 30 seconds, check step 10. If pump still fails to prime, do the following:

a.If impeller is worn, replace it.

b.If pump head is internally worn, replace it.

c.Remember to add one tablespoon of oil every time you start the pump.

NOTICE: When using the Pud-L-Scoop®, inspect the washer in the garden hose fitting to be sure it is in good condition. Be sure connections are air tight.

The Pud-L-Scoop®requires at least 1/2" (12.7mm) minimum water depth to prime.

OPERATION

NOTICE: Do not run pump dry. Pump depends on water being pumped for lubrication. If pump does not prime in less than 30 seconds, recheck installation and plumbing.

Pump will deliver 330 gallons (1249L) per hour (5.5 gallons (20.8L) per minute) when discharge is not restricted. As discharge is restricted and dis- charge pressure increases, capacity will decrease. Do not operate pump continuously at a dis- charge pressure of more than 12 psi (83 kPa) or discharge lift of more than 28’ (8.5M). Motor will exceed the normal safe operating tempera- ture and can heat to 180°-190° F (82°-88° C) when operated continuously at discharge lifts of more than 28’ (8.5M).

Motor overload may trip if motor temperature rises too high. Motor must have air circulation around it for proper cooling. If motor overload trips, allow motor to cool for 30 minutes before attempting to start pump.

Risk of burns. During normal operation, motor case may heat enough to burn you. Do not touch the motor when it is hot.

Plug motor cord into 3-wire grounded 115 volt A.C. outlet 60 Hz.

Risk of fire or explosion if used to pump flammable liquids or if used in explo- sive atmospheres. Pump water only with this pump! Pump is designed to pump

at water temperatures between 32°-77° F (0°-25° C) only.

For parts or assistance, call Simer Customer Service at 1-800-468-7867

Page 2
Image 2
Simer Pumps M40P-01, M40P-03, M40-01 Installation / Operation, For parts or assistance, call Simer Customer Service at

M40P-03, M40-01, M40P-01 specifications

Simer Pumps has long been recognized for its commitment to quality and innovation in the field of water management solutions. Among its impressive lineup, the M40 series, including the M40P-01, M40-01, and M40P-03 models, stands out for its efficiency, reliability, and advanced technological features.

The M40P-01 is engineered for versatility and is particularly suited for applications that require higher water flow rates. This model boasts a powerful motor that provides optimal performance, making it ideal for residential and agricultural applications alike. The M40-01 presents a standard option without compromising on reliability, making it a go-to choice for various applications, from irrigation to water transfer systems.

On the other hand, the M40P-03 is designed with enhanced features for more demanding environments. This model offers a higher pressure capacity, enabling it to tackle tougher jobs and ensuring efficient operation in more extensive systems. Its robust design ensures durability and longevity, allowing users to rely on it even in challenging conditions.

One of the key features across the M40 series is the incorporation of advanced pumping technology. The pumps utilize a self-priming mechanism that significantly simplifies installation and operational procedures. This feature is particularly beneficial for users who need a straightforward solution without complex setups. Additionally, the M40 series is equipped with thermally protected motors, which prevent overheating and contribute to the longevity of the pumps.

The construction of Simer Pumps M40 series reflects a commitment to quality. Made with corrosion-resistant materials, these pumps are suitable for various water types, from clean to slightly contaminated. Their ergonomic design also allows for easy handling and maintenance, ensuring that users can quickly service their pumps when necessary.

In terms of energy efficiency, the M40 series adheres to modern standards, offering optimized performance that helps reduce energy costs. This makes them not only an environmentally friendly choice but also an economically sensible investment for users who prioritize cost-effectiveness.

In summary, the Simer Pumps M40P-01, M40-01, and M40P-03 are exemplary models that showcase the brand's dedication to producing reliable, efficient, and advanced pumping solutions. Whether for residential, agricultural, or industrial uses, these pumps combine cutting-edge technology with practical design, meeting the diverse needs of users across various sectors. Choosing the right pump from the M40 series ensures effective water management and long-term satisfaction.