SM 1619X04464 05-09:SM 1619X04464 05-09 5/20/09 1:54 PM Page 14

OPTIONAL ACCESSORy

Skil model SB18B-LI lithium ion battery pack is compatible with all existing Skil 18V tools that use the SB18B and SB18A Ni-Cd batteries.

! WARNING

Only use the specified charger to charge your Li-Ion batteries. Do not charge Li-

 

ion batteries with a Ni-Cd charger.

 

 

IMPORTANT CHARGING NOTES (LITHIUM-ION BATTERIES)

1.The charger was designed to fast charge the battery only when the battery temperature is between 32˚F (0˚C) and 113˚F (45˚C). If the battery pack is too hot or too cold, the charger will not fast charge the battery. (This may happen if the battery pack is hot from heavy use). When the battery temperature returns to between 32˚F (0˚C) and 113˚F (45˚C), the charger will automatically begin charging.

2.A substantial drop in operating time per charge may mean that the battery pack is nearing the end of its life and should be replaced.

3.Remember to unplug charger during storage period.

4.If battery does not charge properly:

a.Check for voltage at outlet by plugging in some other electrical device.

b.Check to see if outlet is connected to a light switch which turns power “off” when lights are turned off.

c.Check battery pack terminals for dirt. Clean with cotton swab and alcohol if necessary.

d.If you still do not get proper charging, take or send tool, battery pack and charger to your local Skil Service Center. See “Tools, Electric” in the Yellow Pages for names and addresses.

Note: Use of chargers or battery packs not sold by Skil will void the warranty.

BATTERy CHARGE CONDITION INDICATOR LIGHTS (SB18B-LI BATTERy)

Your battery pack is equipped with charge condition indicator lights (Fig. 15). The indicator lights shows the charge condition of the battery during operation.

To check battery charge condition, depress and hold the button on the backside of the battery pack.

 

 

 

FIG. 15

 

* BATTERY

 

 

 

 

CHARGE

 

 

 

 

CONDITION

 

 

 

 

 

* BUTTON

INDICATOR

 

 

 

 

 

LIGHTS

 

 

 

 

LED

Capacity

Continuous lighting 3 x blue

66%

- 100%

Continuous lighting 2 x blue

34 - 65%

Continuous lighting 1 x blue

11 - 33%

Slow flashing 1x blue

0%

- 10%

 

 

 

LED

Error Message

Alternating

Battery temperature is not

left middle

within normal operating

right 1

temperature range of

x blue

0°C (32°F) to 45°C (113°F),

 

or battery current is over

 

the normal operating range.

 

 

CHARGING BATTERy PACK (SC118B-LI CHARGER)

Plug charger cord into your standard power outlet, then insert battery pack into charger (Fig. 16).

If the green indicator light is “ON”,

the charger is plugged in but the battery pack is not inserted, or the

battery pack is fully charged.

If the green indicator light is

“BLINKING”, the battery pack is being fast-charged. Fast- charging will automatically stop when the

battery pack is fully charged.