4. INSTALLATION (CONT)

4. INSTALLATION (CONT)

8. CE

Declaration of Conformity

Note:

-Perform the walk test after you have inserted the battery for more than 1 minute.

-Before performing the walk test, the sensor should not detect any motion.

-After motion is detected once, the sensor will not be triggered unless no motion is detected for 20 seconds. Therefore, wait for at least 20 seconds during walk testing between 2 activations.

DETECTING AREA: (Unit = meter)

14

55°

1.2M

 

55°

12

 

11°

 

 

10

 

 

8

 

 

6

22°

27°

 

22°

4

 

 

2

 

 

M

 

 

 

12°

 

SENSOR

0

1

2

3

4

5

6

7

8

9

10

11

12

13

This equipment complies with the requirements relating to electromagnetic compatibility, EN 301489-3:2002, EN300220-2:2007, EN60950-1:2006, EN50371:2002. This equipment conforms to the essential requirement of the Directive (1999/5/EC) of the European Parliament and of the Council.

9. WARRANTY

If, within one year from date of purchase, this product should become defective (except battery), due to faulty workmanship or materials, it will be repaired or replaced, without charge. Proof of purchase and a Return Authorization are required.

10. CUSTOMER SERVICE

False Trigger:

If you experience false triggering, please pay attention to the following.

-When installing the motion sensor, avoid placing it near heat or cold producing devices (i.e. A/C or furnace vents, fans, ovens, space heaters, etc). Air movement, especially caused by changes in temperature may trigger the Motion Sensor and cause false alarms. Please carefully test your Motion Sensor so that it will only be triggered by wanted movement.

-There is a jumper for sensitivity setting. You may change the sensitivity to low if you experience false triggering.

If you would like to order Skylink’s products or have difficulty getting them to work or download latest information and user manual, please :

1.visit our FAQ section at www.skylinkhome.com, or

2.email us at support@skylinkhome.com

Jumper Location 1

High Sensitivity

Jumper Location 2

Low Sensitivity

 

 

5. OPERATION

The motion sensor is designed to detect the “First Motion”. First Motion means the first movement picked up after 20 seconds without motion detected. So if you continue to walk in front of the motion sensor, it will only pick up the first motion. Unless you wait for 20 seconds, then walk again, the control panel will respond. Otherwise, the control panel will only respond to the first motion.

6. SENSOR FAILURE / LOW BATTERY INDICATION

The control panel constantly monitors its sensors, if the control panel fails to communicate with any sensors, it will begin rapidly flashing the zone LED indicator.

When sensor failure occurs, try the following:

1.Check if the sensor is located at where it should be, and whether there is any physical damage to the sensor.

2.If the failed sensor is not physically damaged, try to activate the sensor and see if the control panel reacts to such activation.

3.If not, try to remove the sensor from its location, and bring it closer to control panel and activate the sensor. It is possible that the sensor is installed too far from the control panel and it cannot establish a steady communication with the control panel. If this is the case, please install the sensor closer to the control panel.

4.Replace the battery of the sensor in that zone if the Control Panel does not respond when the sensor is activated within short range.

If you have multiple sensors in a zone, you may test the function of each sensor to identify which sensor is having problem.

7. OTHER MA SERIES ACCESSORIES

The MA Series control panel can work with different accessories include: Door/Window Sensor, Keychain Remote, Water Sensor, External Keypad, Audio Alarm, Emergency Dialer, etc. Please visit www.skylinkhome.com or contact us at support@skylinkhome.com for more information of how to fully utilize your Wireless Alarm System - MA Series.

CUSTOMER SERVICE

Rm 1303, Block B, Veristrong Industrial Centre, 36 Aupuiwan Street, Fotan, N.T. Hong Kong. Email:sales@skylinkhome.com http://www.skylinkhome.com

P/N. 101Z684

©2009 SKYLINK GROUP

Page 2
Image 2
SkyLink PS-103 8. CE, Warranty, Customer Service, Operation, Sensor Failure / Low Battery Indication, Installation Cont