5. INSTALLATION

5. INSTALLATION

The temperature sensor should be mounted onto the wall by 2 screws. Follow the procedures below:

1.Use a template to mark the location for the 2 screws correctly.

2.Tighten the screws onto the wall half way.

3.Hang the temperature sensor onto the 2 screws.

Note: The temperature sensor is not designed to be used outdoor, it must be installed indoor. To monitor outdoor temperature, an external measuring probe can be used, while the temperature sensor is installed indoor.

6. OPERATION

7. SENSOR FAILURE OR LOW BATTERY (CONT)

When you see the low battery indication, replace the batteries following the procedures below:

1) Remove the screw on the back of the temperature sensor as shown.

2) Rotate the battery compartment, the batteries can be removed.

3) Place the new batteries into the compartment, pay attention on the polarity, as indicated on the diagram.

4) Tighten the screw.

The temperature sensor must be enabled in order to monitor the temperature and communicate with the control panel. You may enable the upper temperature limit only, or lower temperature limit only, or both. To enable the upper or lower temperature limit, simply press “HI” or “LO”. If the display shows “HI”, that means the upper temperature limit is enabled. If the display shows “LO”, that means the lower temperature limit is enabled. If the display shows both “HI” and “LO”, that means both upper and lower temperature limits are enabled. To disable the tempera- ture limits, simply press the same button again, until the “HI” or “LO” doesn’t show up on the display.

External Temperature

If you would like to monitor the external temperature (i.e. outdoor tem- perature), you may use the external measuring probe. Plug in the external testing probe as show on the back of the sensor. Ensure to select the “EXT” on the front panel. If no external measuring probe is plugged in, but “EXT” is selected, the display will not show any temperature.

8. OTHER AAA+TM ACCESSORIES

The AAA+TM control panel can work with different accessories include: Garage door monitorTM sensor, Indoor/outdoor motion sensor, Audio sensor, Remote control, Audio Alarm, etc. Please visit www.skylinkhome.com or contact us at support@skylinkhome.com for more information of how to fully utilize your Temperature Sensor.

9. FCC

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and

(2)This device must accept any interference received, including interference that may cause undesired operation.

WARNING:

Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE:

External Dry Contact (Normal Open)

You may connect the temperature sensor to other devices by the N/O dry contact. Simply plug in the cable into the socket on the back of the sensor as shown. Connect the other end of the cable to the device that you would like to con- nect to. When the temperature is above or below the preset limits, the contact will be closed momentary therefore activating the connected device.

External Dry Contact

External Temperature

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful inter- ference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment dose cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

-Reorient or relocate the receiving antenna.

-Increase the separation between the equipment and receiver.

-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

-Consult the dealer or an experienced radio/TV technician for help.

The maximum ratings of the N/O relay contact is 2A / 24V DC, therefore do not connect an external device which exceeds this rating. The relay contact is not designed for AC connection, DO NOT CONNECT AC DEVICE TO THIS N/O CONTACT.

7.SENSOR FAILURE OR LOW BATTERY

Sensor Failure

The control panel constantly monitors its sensors, if the control panel fails to communicate with any sensors, it will notify the user by:

1.The zone LED of the failed sensor will be on steadily;

2.Voice announcement “zone X sensor Y failure” will be played.

W hen sensor failure occurs, try the following:

1.Check if the sensor is located at where it should be, and whether there is any physical damage to the sensor.

2.If the failed sensor is not physically damaged, try to activate the sensor and see if the control panel reacts to such activation.

3.If not, try to remove the sensor from its location, and bring it closer to control panel and activate the sensor. It is possible that the sensor is installed too far from the control panel and it cannot establish a steady communication with the control panel. If this is the case, please install the sensor closer to the control panel.

10. CE

Declaration of Conformity

This equipment complies with the requirements relating to electromagnetic compatibility, EN 301489-3:2002, EN300220-3:2000. This equipment conforms to the essential requirement of the Directive (1999/5/EC) of the European Parliament and of the Council.

11. WARRANTY

If, within one year from date of purchase, this product should become defective (except battery), due to faulty workmanship or materials, it will be repaired or replaced, without charge. Proof of purchase and a Return Authorization are required.

12. CUSTOMER SERVICE

If you would like to order Skylink’s products or have difficulty getting them to work, please :

1.visit our FAQ section at www.skylinkhome.com, or

2.email us at support@skylinkhome.com, or

3.call our toll free at 1-800-304-1187 from Monday to Friday, 9 am to 5 pm EST. Fax (800) 286-1320

Sensor Low Battery

Two CR-2032 lithium batteries are used to operate the temperature sensor. When the sensor is in low battery condition, the low battery LED indicator will be on. Temperature sensor will also send a wireless low battery signal to the AAA+TM Control Panel.