LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance does not have a pilot. It is equipped with an ignition device that automatically lights the burner. DO NOT try to light the burner by hand.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

DO NOT try to light any appliance.

DO NOT touch any electric switch; DO NOT use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to turn the gas control selector arm. NEVER use tools. If the selector arm will not move by hand, DON'T try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D. DO NOT use this appliance if any part has been under- water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been underwater.

OPERATING INSTRUCTIONS

STOP! Read the safety information above on this label.

Set the room thermostat to lowest setting.

Turn off all electric power to the appliance.

This appliance is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burner by hand.

Remove boiler front cover.

Depress and move gas control selector arm left to “OFF” position. Note: Arm cannot be turned to “OFF” unless arm is pushed in slightly. DO NOT force.

Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to the next step.

Depress and move gas control selector arm right to “ON” position.

Replace boiler front cover.

Turn on all electric power to the appliance.

Set room thermostat to desired setting.

If the appliance will not operate, follow the instructions “To Turn Off Gas To Appliance” and call your service technician or gas supplier.

TO TURN OFF GAS TO APPLIANCE

Set room thermostat to lowest setting.

Turn off all electric power to the appliance if service is to be performed.

Remove boiler front cover.

Depress and move gas control selector arm left to “OFF” position.

Replace boiler front cover.

Selector

 

Arm

ON

 

OFF

Gas Valve 7200 DERN

IMPORTANT SAFETY

INFORMATION FOR YOU

Your boiler must be installed, serviced and repaired by a qualified service technician only. Owner must not attempt to install, service or repair this boiler.

Should overheating occur or the gas supply fail to shut off, DO NOT turn off or disconnect the electrical supply to the pump. Instead, shut off the gas supply at a location external to the appliance.

DO NOT use this boiler if any part has been under- water. Immediately call a qualified service technician to inspect the boiler and to replace any part of the control system and any gas control which has been underwater.

DO NOT attempt to add water to boiler or system. An automatic water feed should have been installed (based on local codes) to maintain proper water level; ask your installer if this device was installed.

Keep boiler area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

DO NOT store anything against the boiler or let anything accumulate in area surrounding the boiler.

DO NOT allow anything to accumulate around or block air flow at outside vent terminal (i.e. leaves, shrubs, snow).

For closet installations, DO NOT allow anything to block air flow at closet ventilation air openings.

DO NOT use water from heating system for cleaning.

DO NOT place clothing on the boiler or venting system to dry.

SLANT/FIN CORPORATION, Greenvale, N.Y. 11548 • Phone: (516) 484-2600

FAX: (516) 484-5921Canada: Slant/Fin LTD/LTEE, Mississauga, Ontario

®

www.slantfin.com

 

Page 4
Image 4
Slant/Fin KC-90, KC-45 manual Important Safety Information for YOU, Lighting Instructions, Operating Instructions

KC-45, KC-90 specifications

The Slant/Fin KC-90 and KC-45 are innovative and highly efficient commercial boilers designed to meet the heating demands of various applications. Known for their advanced engineering and reliability, these units specialize in delivering optimal performance while ensuring energy efficiency and environmental compliance.

One of the standout features of the KC-90 and KC-45 models is their unique design, which incorporates high-efficiency cast iron heat exchangers. This design promotes maximum heat transfer, ensuring that more of the energy consumed is converted into usable heat for a building or industrial application. The cast iron construction also contributes to the durability of the units, allowing them to operate efficiently over an extended lifespan.

Both models are equipped with powerful burners that can accommodate a range of fuel types, including natural gas and propane. This flexibility makes them suitable for a variety of installation scenarios. The burners are designed for easy maintenance, allowing technicians to perform service tasks without significant downtime, thereby improving the overall reliability of the heating system.

In terms of technology, the KC-90 and KC-45 feature integrated electronic controls that enable precise temperature management. These controls allow users to set and maintain desired settings, optimizing energy consumption and leading to cost savings on utility bills. Additionally, the advanced controls can often be integrated with building management systems, offering further capabilities for monitoring and automation.

These boilers also prioritize environmental sustainability. With low NOx emissions, they comply with strict regulatory standards, making them an eco-friendly option for heating large spaces. Their efficient operation not only reduces greenhouse gas emissions but also minimizes the overall carbon footprint of the heating system.

Furthermore, the KC series is designed with user-friendly features, such as convenient access panels for troubleshooting and routine maintenance. This attention to serviceability helps ensure that the systems remain operational and efficient, even in demanding environments.

In conclusion, the Slant/Fin KC-90 and KC-45 boilers exemplify top-tier engineering and technological innovation. With their high-efficiency heat exchangers, flexible fuel options, advanced electronic controls, and commitment to environmental standards, these models are ideal for commercial and industrial heating applications, providing reliable and efficient heating solutions for years to come.