Smeg A36A6PXAA Final Operations, Adjustment of minimum for natural gas, Lubrication of gas taps

Models: A30E6FXAA A21H7D2AA A36A6PXAA

1 12
Download 12 pages 12.58 Kb
Page 9
Image 9
4. FINAL OPERATIONS

Instructions for the installer

4. FINAL OPERATIONS

Having carried out the above adjustments, reassemble the appliance following, backwards, the instructions in paragraph “3.2 Burner and nozzle characteristics table”.

After adjustment to a different kind of gas from the one for which the cooker has been tested, replace the plate inside the heating compartment with one corresponding to the new kind of gas. This plate can be obtained from your nearest Authorised Assistance Centre.

4.1 Adjustment of minimum for natural gas

Light the burner and take it to the minimum. Remove the gas tap knob and turn the adjustment screw inside or at the side of the tap shaft (depending on the model) until there is a regular minimum flame. Replace the knob and check burner flame stability: (rapidly turning the knob from maximum to minimum position, the flame should not go out). Repeat the operation on all the gas taps.

4.2 Regulation of minimum for LPG

To regulate the minimum for LPG, completely tighten (clockwise) the screw inside or next to the gas tap pin (depending on the model).

The diameters of the by-passes for each burner are given in table “3.2 Burner and nozzle characteristics table”.

4.3 Lubrication of gas taps

With time it may happen that the gas taps get blocked and hard to turn. Clean them inside and re-grease them. This operation must be done

by a specialised technician.

23

Page 9
Image 9
Smeg A36A6PXAA, A21H7D2AA, A30E6FXAA Final Operations, Adjustment of minimum for natural gas, Regulation of minimum for LPG