Twin oven model

The appliance comes with a terminal board on the back for electrical hook-up (see following diagram). To open the terminal board cover, remove the fixing screw and raise the cover.

1 - For operation on 230V: use a three- pole H05RR-F type cable (3 x 4 mm2). This is the connection carried out in the factory.

2 - For operation on 230V3N: use a four- pole H05RR-F type cable (4 x 2.5 mm2).

3 - For operation on 400V2N: use a four- pole H05RR-F type cable (4 x 2.5 mm2).

The cable end to be connected to the appliance must be provided with an ground wire (yellow-green) at least 20 mm longer.