2. INSTALLATION OF THE OVEN

The oven must be set up on a perfectly flat surface and left standing free. Make sure to allow enough room at the back for easy access to the

terminal strip for connection of the power cable to mains.

Installation must be carried out by a qualified technician in compliance with applicable regulations in force.

Keep the appliance at least 5 cm from any walls at the sides and back.

2.1 Electrical connection

Make sure that the power line voltage matches the specifications indicated on the rating plate located to the rear of the oven. This rating plate must never be removed.

The oven is supplied complete with a H07RN-F three-core supply cable for operation from a 220-240Vpower supply.

For operation from a 380- 415V2Nor 380-415V3Npower supply, the original cable must be replaced and the terminal board connections modified accordingly. For access to the terminal board, remove the door located at the back of the oven.

The standard cable is of the three-core 3 x

4 mm2 H07RN-F type.

For operation from a 380-415V2No 380- 415V3Npower supply, replace the standard

cable with one of the H07RN-F type. The cross section of the leads of the latter cable must not be less than 2.5-1.5 mm2 (4 x 2.5 mm2 - 5 x 1.5 mm2); the ground (yellow-green) of the termination to be linked up to the oven must be at least 20 mm longer.